国际口腔医学杂志 ›› 2020, Vol. 47 ›› Issue (2): 212-218.doi: 10.7518/gjkq.2020010
摘要:
在口腔正畸治疗中,支抗对于正畸载荷的施加是必不可少的。微型种植体支抗作为当下最广泛应用的支抗手段,患者个体情况、支抗体本身设计、植入前准备、植入技术以及植入后加载都能影响植入的稳定性,而其稳定性又与正畸治疗的效率和质量息息相关。植入的失败不仅会增加患者的痛苦,还会提升治疗成本,延长治疗时间,阻碍正畸治疗的进程。通过对稳定性影响因素的研究,减少不利因素的产生,可以提升微型种植支抗的植入成功率,以达到更加专业、精准的正畸治疗。本文就微型种植体支抗的稳定性及其影响因素的研究进展作一综述。
中图分类号:
[1] | Branemark I, Breine U, Adell R , et al. Intra-osseous anchorage of dental prostheses.Ⅰ. Experimental studies[J]. Plast Reconstr Surg, 1971,48(1):97-98. |
[2] | Choi SH, Kim SJ, Lee KJ , et al. Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles[J]. Korean J Orthod, 2016,46(4):189-198. |
[3] | Baumgaertel S, Hans MG . Buccal cortical bone thic-kness for mini-implant placement[J]. Am J Orthod Dentofacial Orthop, 2009,136(2):230-235. |
[4] | Wang ZQ, Zhao ZH, Xue J , et al. Pullout strength of miniscrews placed in anterior mandibles of adult and adolescent dogs: a microcomputed tomographic ana-lysis[J]. Am J Orthod Dentofacial Orthop, 2010,137(1):100-107. |
[5] | Chopra SS, Chakranarayan A . Clinical evaluation of immediate loading of titanium orthodontic implants[J]. Med J Armed Forces India, 2015,71(2):165-170. |
[6] | Farnsworth D, Rossouw PE, Ceen RF , et al. Cortical bone thickness at common miniscrew implant placement sites[J]. Am J Orthod Dentofacial Orthop, 2011,139(4):495-503. |
[7] | Tozlu M, Germeç Cakan D, Ulkur F , et al. Maxillary buccal cortical plate inclination at mini-screw inser-tion sites[J]. Angle Orthod, 2015,85(5):868-873. |
[8] | Cassetta M, Sofan AA, Altieri F , et al. Evaluation of alveolar cortical bone thickness and density for or-thodontic mini-implant placement[J]. J Clin Exp Dent, 2013,5(5):e245-e252. |
[9] | Lim JE, Lee SJ, Kim YJ , et al. Comparison of cortical bone thickness and root proximity at maxillary and mandibular interradicular sites for orthodontic mini-implant placement[J]. Orthod Craniofac Res, 2009,12(4):299-304. |
[10] | Zhao H, Gu XM, Liu HC , et al. Measurement of cortical bone thickness in adults by cone-beam com-puterized tomography for orthodontic miniscrews placement[J]. J Huazhong Univ Sci Technol (Med Sci), 2013,33(2):303-308. |
[11] | Alrbata RH, Yu W, Kyung HM . Biomechanical effe-ctiveness of cortical bone thickness on orthodontic microimplant stability: an evaluation based on the load share between cortical and cancellous bone[J]. Am J Orthod Dentofacial Orthop, 2014,146(2):175-182. |
[12] | Tseng YC, Hsieh CH, Chen CH , et al. The applica-tion of mini-implants for orthodontic anchorage[J]. Int J Oral Maxillofac Surg, 2006,35(8):704-707. |
[13] | Park HS, Jeong SH, Kwon OW . Factors affecting the clinical success of screw implants used as orthodontic anchorage[J]. Am J Orthod Dentofacial Orthop, 2006,130(1):18-25. |
[14] | Papadopoulos MA, Papageorgiou SN, Zogakis IP . Clinical effectiveness of orthodontic miniscrew im-plants: a meta-analysis[J]. J Dent Res, 2011,90(8):969-976. |
[15] | Tepedino M, Masedu F, Chimenti C . Comparative evaluation of insertion torque and mechanical sta-bility for self-tapping and self-drilling orthodontic miniscrews—an in vitro study[J]. Head Face Med, 2017,13(1):10. |
[16] | Zhang Q, Zhao LX, Wu YK , et al. The effect of var-ying healing times on orthodontic mini-implant sta-bility: a microscopic computerized tomographic and biomechanical analysis[J]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2011,112(4):423-429. |
[17] | Katić V, Kamenar E, Blažević D , et al. Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque[J]. Korean J Orthod, 2014,44(4):177-183. |
[18] | Meira TM, Tanaka OM, Ronsani MM , et al. Insertion torque, pull-out strength and cortical bone thickness in contact with orthodontic mini-implants at different insertion angles[J]. Eur J Orthod, 2013,35(6):766-771. |
[19] | Marquezan M, Mattos CT, Sant’Anna EF , et al. Does cortical thickness influence the primary stability of miniscrews? A systematic review and meta-analysis[J]. Angle Orthod, 2014,84(6):1093-1103. |
[20] | Holm L, Cunningham SJ, Petrie A , et al. An in vitro study of factors affecting the primary stability of orthodontic mini-implants[J]. Angle Orthod, 2012,82(6):1022-1028. |
[21] | Xu ZR, Wu YK, Zhao LX , et al. Effect of placement Angle on the stability of loaded titanium microscrews in beagle jaws[J]. Angle Orthod, 2013,83(4):659-666. |
[22] | Zhao LX, Xu ZR, Wei X , et al. Effect of placement Angle on the stability of loaded titanium microscrews: a microcomputed tomographic and biomechanical analysis[J]. Am J Orthod Dentofacial Orthop, 2011,139(5):628-635. |
[23] | Araghbidikashani M, Golshah A, Nikkerdar N , et al. In-vitro impact of insertion Angle on primary stability of miniscrews[J]. Am J Orthod Dentofacial Orthop, 2016,150(3):436-443. |
[24] | Romano FL, Consolaro A. Why are mini-implants lost: the value of the implantation technique[J]. Dental Press J Orthod, 2015,20(1):23-29. |
[25] | Motoyoshi M, Uchida Y, Inaba M , et al. Are assess-ments of damping capacity and placement torque useful in estimating root proximity of orthodontic anchor screws[J]. Am J Orthod Dentofacial Orthop, 2016,150(1):124-129. |
[26] | Motoyoshi M, Uemura M, Ono A , et al. Factors affe-cting the long-term stability of orthodontic mini-implants[J]. Am J Orthod Dentofacial Orthop, 2010, 137(5):588.e1-588.e5. |
[27] | Motoyoshi M . Clinical indices for orthodontic mini-implants[J]. J Oral Sci, 2011,53(4):407-412. |
[28] | 于海璐, 蔡兴伟, 马龙 , 等. 不同植入角度及载荷方向对微种植体稳定性影响的三维有限元分析[J]. 解放军医学院学报, 2016,37(3):261-265, 270. |
Yu HL, Cai XW, Ma L , et al. Effect of inserting An-gle and direction of orthodontic force on stability of micro-implants evaluated by 3-dimensional finite element analysis[J]. Acad J Chin PLA Med Sch, 2016,37(3):261-265, 270. | |
[29] | Mohammed H, Wafaie K, Rizk MZ , et al. Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a syste-matic review and meta-analysis[J]. Prog Orthod, 2018,19(1):36. |
[30] | 孙吉成, 胡赟, 郑雷蕾 , 等. 拔牙创愈合对邻近微种植体骨界面生长因子影响的研究[J]. 四川大学学报(医学版), 2015,46(2):222-227. |
Sun JC, Hu Y, Zheng LL , et al. Influence of healing process of extraction on related growth factors in microscrew-bone interface of implanted titanium microscrews near the extraction wounds[J]. J Sichuan Univ (Med Sci Ed), 2015,46(2):222-227. | |
[31] | Son S, Motoyoshi M, Uchida Y , et al. Comparative study of the primary stability of self-drilling and self-tapping orthodontic miniscrews[J]. Am J Orthod Dentofacial Orthop, 2014,145(4):480-485. |
[32] | Sharifi M, Ghassemi A, Bayani S . Effect of insertion method and postinsertion time interval prior to force application on the removal torque of orthodontic miniscrews[J]. Int J Oral Maxillofac Implants, 2015,30(1):35-40. |
[33] | Duaibis R, Kusnoto B, Natarajan R , et al. Factors affecting stresses in cortical bone around miniscrew implants: a three-dimensional finite element study[J]. Angle Orthod, 2012,82(5):875-880. |
[34] | 常少海, 常岚如, 张健娜 , 等. 转矩力作用下不同颈部构型对微种植体稳定性的影响[J]. 中山大学学报(医学科学版), 2016,37(2):248-253. |
Chang SH, Chang LR, Zhang JN , et al. Influence of neck design on mini-implant primary stability after loading with torque force[J]. J Sun Yat-sen Univ (Med Sci), 2016,37(2):248-253. | |
[35] | Scribante A, Montasser MA, Radwan ES , et al. Reliability of orthodontic miniscrews: bending and maximum load of different Ti-6Al-4V titanium and stainless steel temporary anchorage devices (TADs)[J]. Materials (Basel), 2018,11(7). doi: 10.3390/ma11071138. |
[36] | Radwan ES, Montasser MA, Maher A . Influence of geometric design characteristics on primary stability of orthodontic miniscrews[J]. J Orofac Orthop, 2018,79(3):191-203. |
[37] | Motoyoshi M, Yano S, Tsuruoka T , et al. Biomechanical effect of abutment on stability of orthodontic mini-implant. A finite element analysis[J]. Clin Oral Im-plants Res, 2005,16(4):480-485. |
[38] | Miyawaki S, Tomonari H, Yagi T , et al. Development of a novel spike-like auxiliary skeletal anchorage de- vice to enhance miniscrew stability[J]. Am J Orthod Dentofacial Orthop, 2015,148(2):338-344. |
[39] | 张强, 李平, 刘静 . 种植体周围炎危险因素及其预防研究进展[J]. 全科口腔医学电子杂志, 2018,5(14):19-21. |
Zhang Q, Li P, Liu J . Research progress on risk fac-tors and prevention of peri-implant inflammation[J]. Gen J Stomatol, 2018,5(14):19-21. | |
[40] | Oh HJ, Cha JY, Yu HS , et al. Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root pro-ximity[J]. Korean J Orthod, 2018,48(5):283-291. |
[41] | Suzuki M, Deguchi T, Watanabe H , et al. Evaluation of optimal length and insertion torque for miniscrews[J]. Am J Orthod Dentofacial Orthop, 2013,144(2):251-259. |
[42] | Albogha MH, Takahashi I . Effect of loaded orthodontic miniscrew implant on compressive stresses in adja-cent periodontal ligament[J]. Angle Orthod, 2019,89(2):235-241. |
[43] | Cho UH, Yu W, Kyung HM . Root contact during drilling for microimplant placement. Affect of sur-gery site and operator expertise[J]. Angle Orthod, 2010,80(1):130-136. |
[44] | Shigeeda T . Root proximity and stability of orthodontic anchor screws[J]. J Oral Sci, 2014,56(1):59-65. |
[45] | Inaba M . Evaluation of primary stability of inclined orthodontic mini-implants[J]. J Oral Sci, 2009,51(3):347-353. |
[46] | Shan LH, Guo N, Zhou GJ , et al. Finite element ana-lysis of bone stress for miniscrew implant proximal to root under occlusal force and implant loading[J]. J Craniofac Surg, 2015,26(7):2072-2076. |
[47] | Jeong JW, Kim JW, Lee NK , et al. Analysis of time to failure of orthodontic mini-implants after insertion or loading[J]. J Korean Assoc Oral Maxillofac Surg, 2015,41(5):240-245. |
[48] | Zhang LK, Zhao ZH, Li Y , et al. Osseointegration of orthodontic micro-screws after immediate and early loading[J]. Angle Orthod, 2010,80(2):354-360. |
[49] | 常立军, 唐甜, 张晓歌 , 等. 正畸应力刺激下Beagle犬微种植体周围炎的牙周组织变化[J]. 中国组织工程研究, 2018,22(34):5464-5468. |
Chang LJ, Tang T, Zhang XG , et al. Periodontal tissue changes in a Beagle dog model of peri-implantitis under orthodontic force[J]. Chin J Tissue Eng Res, 2018,22(34):5464-5468. | |
[50] | 王雨薇, 王了, 包崇云 . 种植体颈部的优化设计在预防种植体周围炎中的应用[J]. 口腔医学, 2018,38(2):177-180. |
Wang YW, Wang L, Bao CY . Effect of cervical design of dental implant on peri-implantitis[J]. Stomatology, 2018,38(2):177-180. |
[1] | 和子慕, 李风兰. 数字化口腔定位支架在头颈部肿瘤放射治疗中的应用现状[J]. 国际口腔医学杂志, 2024, 51(1): 28-35. |
[2] | 傅豫, 何薇, 黄兰. 铁死亡在口腔疾病中的研究进展[J]. 国际口腔医学杂志, 2024, 51(1): 36-44. |
[3] | 李然,胡月,张宁,高瑞芳,王翔宇,葛学军. Toll样受体和白细胞介素-17单核苷酸多态性与口腔扁平苔藓易感性的相关性研究[J]. 国际口腔医学杂志, 2024, 51(1): 45-51. |
[4] | 周金阔,张晋弘,史晓晶,刘广顺,姜磊,刘倩峰. 长链非编码RNA小核仁RNA宿主基因22调控微小RNA-27b-3p对口腔鳞状细胞癌细胞增殖、侵袭和迁移的影响[J]. 国际口腔医学杂志, 2024, 51(1): 52-59. |
[5] | 李立恒,王蕊,王晓明,张智轶,张璇,安峰,王芹,张凡. 环状RNA hsa_circ_0085576调控微小RNA-498/B细胞特异性莫洛尼鼠白血病病毒整合位点1轴对口腔鳞状细胞癌细胞迁移和侵袭的影响[J]. 国际口腔医学杂志, 2024, 51(1): 60-67. |
[6] | 谭永臻,梁新华. 口腔局部麻醉药抗菌机制的研究进展[J]. 国际口腔医学杂志, 2024, 51(1): 74-81. |
[7] | 王楠楠,贺红,花放. 正畸相关釉质脱矿危险因素的研究进展[J]. 国际口腔医学杂志, 2024, 51(1): 91-98. |
[8] | 韩冲,何东宁,余飞燕,吴东潮. 口腔种植术后疼痛机制及治疗的研究进展[J]. 国际口腔医学杂志, 2024, 51(1): 99-106. |
[9] | 徐书奎,张珊,谢新宇,马文盛. 上颌前方牵引矫治骨性Ⅲ类错畸形远期疗效稳定性的研究进展[J]. 国际口腔医学杂志, 2023, 50(6): 646-652. |
[10] | 王素杰,谭芹,韦渊,王洁,范杰,岳二丽. 口腔扁平苔藓患者血清血管生成素-2水平与叉头翼状螺旋转录因子阳性调节性T细胞及疾病活动度的相关性分析[J]. 国际口腔医学杂志, 2023, 50(6): 674-678. |
[11] | 吴佳敏,夏斌,杨禾丰,许彪. 癌相关成纤维细胞在口腔鳞状细胞癌微环境中作用的研究进展[J]. 国际口腔医学杂志, 2023, 50(6): 711-717. |
[12] | 柳江龙, 买买提吐逊·吐尔地. 超声造影在口腔鳞状细胞癌颈部转移性淋巴结诊断中的研究进展[J]. 国际口腔医学杂志, 2023, 50(5): 514-520. |
[13] | 刘婷,武秀萍. 唐氏综合征的口腔-颅颌面表征及治疗进展[J]. 国际口腔医学杂志, 2023, 50(5): 618-622. |
[14] | 姜玥莹,何宇添,李婷,周蓉卉. 近红外荧光探针在口腔癌诊断中应用的研究进展[J]. 国际口腔医学杂志, 2023, 50(4): 407-413. |
[15] | 王铝亚,张竞心,林洁. 口腔术后聚维酮碘与氯己定控制感染效果的系统评价分析[J]. 国际口腔医学杂志, 2023, 50(4): 438-444. |
|