Research progress on stability of mini-implants in orthodontic treatments

Tian Qinglu1,Zhao Zhihe2()   

  1. 1. State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & West China School of Stomatology, Sichuan University, Chengdu 610041, China
    2. State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Dept. of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
  • Received:2019-06-27 Revised:2019-09-27 Online:2020-03-01 Published:2020-03-12
  • Contact: Zhihe Zhao E-mail:zhaozhihe@vip.163.com

Abstract:

Anchorage is indispensable for the loading during orthodontic treatments. Temporary anchorage devices (TADs) are widely used for such treatment. The stability of these devices is closely linked to treatment efficiency and quality and can be affected by several factors, such as the patient’s individual condition, the design of TADs, the preparation before implantation, implantation techniques, and the loading after implantation. These factors are reviewed in this study. TAD implanting failures can worsen patients’ suffering and increase the cost, prolong treatment time, and hinder the progress of orthodontic treatment. The success rate of implantation can be improved to a certain degree by controlling the adverse factors influencing TAD stability to achieve a precise and professional-grade orthodontic treatment.

Key words: orthodontic mini-implants, anchorage, oral, stability

CLC Number: 

  • R783.5

TrendMD: 
[1] Branemark I, Breine U, Adell R , et al. Intra-osseous anchorage of dental prostheses.Ⅰ. Experimental studies[J]. Plast Reconstr Surg, 1971,48(1):97-98.
[2] Choi SH, Kim SJ, Lee KJ , et al. Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles[J]. Korean J Orthod, 2016,46(4):189-198.
[3] Baumgaertel S, Hans MG . Buccal cortical bone thic-kness for mini-implant placement[J]. Am J Orthod Dentofacial Orthop, 2009,136(2):230-235.
[4] Wang ZQ, Zhao ZH, Xue J , et al. Pullout strength of miniscrews placed in anterior mandibles of adult and adolescent dogs: a microcomputed tomographic ana-lysis[J]. Am J Orthod Dentofacial Orthop, 2010,137(1):100-107.
[5] Chopra SS, Chakranarayan A . Clinical evaluation of immediate loading of titanium orthodontic implants[J]. Med J Armed Forces India, 2015,71(2):165-170.
[6] Farnsworth D, Rossouw PE, Ceen RF , et al. Cortical bone thickness at common miniscrew implant placement sites[J]. Am J Orthod Dentofacial Orthop, 2011,139(4):495-503.
[7] Tozlu M, Germeç Cakan D, Ulkur F , et al. Maxillary buccal cortical plate inclination at mini-screw inser-tion sites[J]. Angle Orthod, 2015,85(5):868-873.
[8] Cassetta M, Sofan AA, Altieri F , et al. Evaluation of alveolar cortical bone thickness and density for or-thodontic mini-implant placement[J]. J Clin Exp Dent, 2013,5(5):e245-e252.
[9] Lim JE, Lee SJ, Kim YJ , et al. Comparison of cortical bone thickness and root proximity at maxillary and mandibular interradicular sites for orthodontic mini-implant placement[J]. Orthod Craniofac Res, 2009,12(4):299-304.
[10] Zhao H, Gu XM, Liu HC , et al. Measurement of cortical bone thickness in adults by cone-beam com-puterized tomography for orthodontic miniscrews placement[J]. J Huazhong Univ Sci Technol (Med Sci), 2013,33(2):303-308.
[11] Alrbata RH, Yu W, Kyung HM . Biomechanical effe-ctiveness of cortical bone thickness on orthodontic microimplant stability: an evaluation based on the load share between cortical and cancellous bone[J]. Am J Orthod Dentofacial Orthop, 2014,146(2):175-182.
[12] Tseng YC, Hsieh CH, Chen CH , et al. The applica-tion of mini-implants for orthodontic anchorage[J]. Int J Oral Maxillofac Surg, 2006,35(8):704-707.
[13] Park HS, Jeong SH, Kwon OW . Factors affecting the clinical success of screw implants used as orthodontic anchorage[J]. Am J Orthod Dentofacial Orthop, 2006,130(1):18-25.
[14] Papadopoulos MA, Papageorgiou SN, Zogakis IP . Clinical effectiveness of orthodontic miniscrew im-plants: a meta-analysis[J]. J Dent Res, 2011,90(8):969-976.
[15] Tepedino M, Masedu F, Chimenti C . Comparative evaluation of insertion torque and mechanical sta-bility for self-tapping and self-drilling orthodontic miniscrews—an in vitro study[J]. Head Face Med, 2017,13(1):10.
[16] Zhang Q, Zhao LX, Wu YK , et al. The effect of var-ying healing times on orthodontic mini-implant sta-bility: a microscopic computerized tomographic and biomechanical analysis[J]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2011,112(4):423-429.
[17] Katić V, Kamenar E, Blažević D , et al. Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque[J]. Korean J Orthod, 2014,44(4):177-183.
[18] Meira TM, Tanaka OM, Ronsani MM , et al. Insertion torque, pull-out strength and cortical bone thickness in contact with orthodontic mini-implants at different insertion angles[J]. Eur J Orthod, 2013,35(6):766-771.
[19] Marquezan M, Mattos CT, Sant’Anna EF , et al. Does cortical thickness influence the primary stability of miniscrews? A systematic review and meta-analysis[J]. Angle Orthod, 2014,84(6):1093-1103.
[20] Holm L, Cunningham SJ, Petrie A , et al. An in vitro study of factors affecting the primary stability of orthodontic mini-implants[J]. Angle Orthod, 2012,82(6):1022-1028.
[21] Xu ZR, Wu YK, Zhao LX , et al. Effect of placement Angle on the stability of loaded titanium microscrews in beagle jaws[J]. Angle Orthod, 2013,83(4):659-666.
[22] Zhao LX, Xu ZR, Wei X , et al. Effect of placement Angle on the stability of loaded titanium microscrews: a microcomputed tomographic and biomechanical analysis[J]. Am J Orthod Dentofacial Orthop, 2011,139(5):628-635.
[23] Araghbidikashani M, Golshah A, Nikkerdar N , et al. In-vitro impact of insertion Angle on primary stability of miniscrews[J]. Am J Orthod Dentofacial Orthop, 2016,150(3):436-443.
[24] Romano FL, Consolaro A. Why are mini-implants lost: the value of the implantation technique[J]. Dental Press J Orthod, 2015,20(1):23-29.
[25] Motoyoshi M, Uchida Y, Inaba M , et al. Are assess-ments of damping capacity and placement torque useful in estimating root proximity of orthodontic anchor screws[J]. Am J Orthod Dentofacial Orthop, 2016,150(1):124-129.
[26] Motoyoshi M, Uemura M, Ono A , et al. Factors affe-cting the long-term stability of orthodontic mini-implants[J]. Am J Orthod Dentofacial Orthop, 2010, 137(5):588.e1-588.e5.
[27] Motoyoshi M . Clinical indices for orthodontic mini-implants[J]. J Oral Sci, 2011,53(4):407-412.
[28] 于海璐, 蔡兴伟, 马龙 , 等. 不同植入角度及载荷方向对微种植体稳定性影响的三维有限元分析[J]. 解放军医学院学报, 2016,37(3):261-265, 270.
Yu HL, Cai XW, Ma L , et al. Effect of inserting An-gle and direction of orthodontic force on stability of micro-implants evaluated by 3-dimensional finite element analysis[J]. Acad J Chin PLA Med Sch, 2016,37(3):261-265, 270.
[29] Mohammed H, Wafaie K, Rizk MZ , et al. Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a syste-matic review and meta-analysis[J]. Prog Orthod, 2018,19(1):36.
[30] 孙吉成, 胡赟, 郑雷蕾 , 等. 拔牙创愈合对邻近微种植体骨界面生长因子影响的研究[J]. 四川大学学报(医学版), 2015,46(2):222-227.
Sun JC, Hu Y, Zheng LL , et al. Influence of healing process of extraction on related growth factors in microscrew-bone interface of implanted titanium microscrews near the extraction wounds[J]. J Sichuan Univ (Med Sci Ed), 2015,46(2):222-227.
[31] Son S, Motoyoshi M, Uchida Y , et al. Comparative study of the primary stability of self-drilling and self-tapping orthodontic miniscrews[J]. Am J Orthod Dentofacial Orthop, 2014,145(4):480-485.
[32] Sharifi M, Ghassemi A, Bayani S . Effect of insertion method and postinsertion time interval prior to force application on the removal torque of orthodontic miniscrews[J]. Int J Oral Maxillofac Implants, 2015,30(1):35-40.
[33] Duaibis R, Kusnoto B, Natarajan R , et al. Factors affecting stresses in cortical bone around miniscrew implants: a three-dimensional finite element study[J]. Angle Orthod, 2012,82(5):875-880.
[34] 常少海, 常岚如, 张健娜 , 等. 转矩力作用下不同颈部构型对微种植体稳定性的影响[J]. 中山大学学报(医学科学版), 2016,37(2):248-253.
Chang SH, Chang LR, Zhang JN , et al. Influence of neck design on mini-implant primary stability after loading with torque force[J]. J Sun Yat-sen Univ (Med Sci), 2016,37(2):248-253.
[35] Scribante A, Montasser MA, Radwan ES , et al. Reliability of orthodontic miniscrews: bending and maximum load of different Ti-6Al-4V titanium and stainless steel temporary anchorage devices (TADs)[J]. Materials (Basel), 2018,11(7). doi: 10.3390/ma11071138.
[36] Radwan ES, Montasser MA, Maher A . Influence of geometric design characteristics on primary stability of orthodontic miniscrews[J]. J Orofac Orthop, 2018,79(3):191-203.
[37] Motoyoshi M, Yano S, Tsuruoka T , et al. Biomechanical effect of abutment on stability of orthodontic mini-implant. A finite element analysis[J]. Clin Oral Im-plants Res, 2005,16(4):480-485.
[38] Miyawaki S, Tomonari H, Yagi T , et al. Development of a novel spike-like auxiliary skeletal anchorage de- vice to enhance miniscrew stability[J]. Am J Orthod Dentofacial Orthop, 2015,148(2):338-344.
[39] 张强, 李平, 刘静 . 种植体周围炎危险因素及其预防研究进展[J]. 全科口腔医学电子杂志, 2018,5(14):19-21.
Zhang Q, Li P, Liu J . Research progress on risk fac-tors and prevention of peri-implant inflammation[J]. Gen J Stomatol, 2018,5(14):19-21.
[40] Oh HJ, Cha JY, Yu HS , et al. Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root pro-ximity[J]. Korean J Orthod, 2018,48(5):283-291.
[41] Suzuki M, Deguchi T, Watanabe H , et al. Evaluation of optimal length and insertion torque for miniscrews[J]. Am J Orthod Dentofacial Orthop, 2013,144(2):251-259.
[42] Albogha MH, Takahashi I . Effect of loaded orthodontic miniscrew implant on compressive stresses in adja-cent periodontal ligament[J]. Angle Orthod, 2019,89(2):235-241.
[43] Cho UH, Yu W, Kyung HM . Root contact during drilling for microimplant placement. Affect of sur-gery site and operator expertise[J]. Angle Orthod, 2010,80(1):130-136.
[44] Shigeeda T . Root proximity and stability of orthodontic anchor screws[J]. J Oral Sci, 2014,56(1):59-65.
[45] Inaba M . Evaluation of primary stability of inclined orthodontic mini-implants[J]. J Oral Sci, 2009,51(3):347-353.
[46] Shan LH, Guo N, Zhou GJ , et al. Finite element ana-lysis of bone stress for miniscrew implant proximal to root under occlusal force and implant loading[J]. J Craniofac Surg, 2015,26(7):2072-2076.
[47] Jeong JW, Kim JW, Lee NK , et al. Analysis of time to failure of orthodontic mini-implants after insertion or loading[J]. J Korean Assoc Oral Maxillofac Surg, 2015,41(5):240-245.
[48] Zhang LK, Zhao ZH, Li Y , et al. Osseointegration of orthodontic micro-screws after immediate and early loading[J]. Angle Orthod, 2010,80(2):354-360.
[49] 常立军, 唐甜, 张晓歌 , 等. 正畸应力刺激下Beagle犬微种植体周围炎的牙周组织变化[J]. 中国组织工程研究, 2018,22(34):5464-5468.
Chang LJ, Tang T, Zhang XG , et al. Periodontal tissue changes in a Beagle dog model of peri-implantitis under orthodontic force[J]. Chin J Tissue Eng Res, 2018,22(34):5464-5468.
[50] 王雨薇, 王了, 包崇云 . 种植体颈部的优化设计在预防种植体周围炎中的应用[J]. 口腔医学, 2018,38(2):177-180.
Wang YW, Wang L, Bao CY . Effect of cervical design of dental implant on peri-implantitis[J]. Stomatology, 2018,38(2):177-180.
[1] He Zimu, Li Fenglan. Present application of digital oral positioning stents in radiotherapy of head and neck tumor [J]. Int J Stomatol, 2024, 51(1): 28-35.
[2] Fu Yu, He Wei, Huang Lan. Ferroptosis and its implication in oral diseases [J]. Int J Stomatol, 2024, 51(1): 36-44.
[3] Li Ran,Hu Yue,Zhang Ning,Gao Ruifang,Wang Xiangyu,Ge Xuejun. The correlation study between single nucleotide polymorphisms of Toll-like receptor and interleukin-17 and oral lichen planus [J]. Int J Stomatol, 2024, 51(1): 45-51.
[4] Zhou Jinkuo,Zhang Jinhong,Shi Xiaojing,Liu Guangshun,Jiang Lei,Liu Qianfeng. Influences of long noncoding RNA small nucleolar RNA host gene 22 on the cell proliferation, invasion and migration of oral squamous carcinoma cells by regulating microRNA-27b-3p [J]. Int J Stomatol, 2024, 51(1): 52-59.
[5] Li Liheng,Wang Rui,Wang Xiaoming,Zhang Zhiyi,Zhang Xuan,An Feng,Wang Qin,Zhang Fan. Effects of circular RNA hsa_circ_0085576 on cell migration and invasion of oral squamous cell carcinoma by regulating the microRNA-498/B-cell-specific Moloney murine leukemia virus integration site 1 axis [J]. Int J Stomatol, 2024, 51(1): 60-67.
[6] Xia Weiyao,Jia Zhonglin. Research progress on the relationship between vitamin and oral clefts [J]. Int J Stomatol, 2023, 50(6): 632-638.
[7] Xu Shukui,Zhang Shan,Xie Xinyu,Ma Wensheng.. Progress in research into the long-term stability of maxillary protraction therapy in skeletal classmalocclusion [J]. Int J Stomatol, 2023, 50(6): 646-652.
[8] Wang Sujie,Tan Qin,Wei Yuan,Wang Jie,Fan Jie,Yue Erli.. Correlation analysis of serum angiopoietin-2 level with forkhead/winged helix transcription factor p3 regulatory T cells and disease activity in patients with oral lichen planus [J]. Int J Stomatol, 2023, 50(6): 674-678.
[9] Wu Jiamin,Xia Bin,Yang Hefeng,Xu Biao.. Research progress on cancer-associated fibroblasts in the tumor microenvironment of oral squamous cell carcinoma [J]. Int J Stomatol, 2023, 50(6): 711-717.
[10] Liu Jianglong, Tuerdi Maimaitituxun. Progress of contrast-enhanced ultrasound in the diagnosis of cervical lymph node metastasis from oral squamous cell carcinoma [J]. Int J Stomatol, 2023, 50(5): 514-520.
[11] Liu Ting,Wu Xiuping.. Research progress on oral-craniomaxillofacial features and treatment of Down syndrome [J]. Int J Stomatol, 2023, 50(5): 618-622.
[12] Jiang Yueying,He Yutian,Li Ting,Zhou Ronghui.. Research progress on the application of near infrared fluorescence probe in the diagnosis of oral cancer [J]. Int J Stomatol, 2023, 50(4): 407-413.
[13] Wang Lüya,Zhang Jingxin,Lin Jie.. Postoperative infection control effect of povidone iodine and chlorhexidine: a systematic review and analysis [J]. Int J Stomatol, 2023, 50(4): 438-444.
[14] Fan Lin,Sun Jiang.. Application of microneedles in stomatology [J]. Int J Stomatol, 2023, 50(4): 472-478.
[15] He Jing,Hu Mingjia,Xiao Ning,Li Jia,Sun Wanxin,Ling Lü,Liu Fan. Investigation on the degree of psychological distress and its influencing factors in patients with oral lichen planus [J]. Int J Stomatol, 2023, 50(3): 308-313.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] . [J]. Foreign Med Sci: Stomatol, 1999, 26(06): .
[2] . [J]. Foreign Med Sci: Stomatol, 1999, 26(05): .
[3] . [J]. Foreign Med Sci: Stomatol, 1999, 26(05): .
[4] . [J]. Foreign Med Sci: Stomatol, 1999, 26(05): .
[5] . [J]. Foreign Med Sci: Stomatol, 1999, 26(05): .
[6] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .
[7] . [J]. Foreign Med Sci: Stomatol, 2005, 32(06): 458 -460 .
[8] . [J]. Foreign Med Sci: Stomatol, 2005, 32(06): 452 -454 .
[9] . [J]. Inter J Stomatol, 2008, 35(S1): .
[10] . [J]. Inter J Stomatol, 2008, 35(S1): .