国际口腔医学杂志 ›› 2026, Vol. 53 ›› Issue (3): 416-423.doi: 10.7518/gjkq.2026109

• 综述 • 上一篇    

种植基台的表面污染及其处理方法的研究进展

王小霞1(),岳莉1,朱卓立2()   

  1. 1.口腔疾病防治全国重点实验室;国家口腔医学中心 口腔疾病国家临床医学研究中心;四川大学华西口腔医院口腔修复工艺科 成都 610041
    2.口腔疾病防治全国重点实验室;国家口腔医学中心 口腔疾病国家临床医学研究中心;四川大学华西口腔医院老年口腔科 成都 610041
  • 收稿日期:2024-10-10 修回日期:2025-07-16 出版日期:2026-05-01 发布日期:2026-04-24
  • 通讯作者: 朱卓立
  • 作者简介:王小霞,硕士,Email:2521609541@qq.com
  • 基金资助:
    四川省卫生健康委员会项目(川干研 2024-901)

Research progress on the surface contamination of implant abutments and their treatment methods

Xiaoxia Wang1(),Li Yue1,Zhuoli Zhu2()   

  1. 1.State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Dept. of Dental Technology, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
    2.State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Dept. of Geriatric Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
  • Received:2024-10-10 Revised:2025-07-16 Online:2026-05-01 Published:2026-04-24
  • Contact: Zhuoli Zhu
  • Supported by:
    Project of Health Commission of Sichuan Province(ChuanGanYan 2024-901)

摘要:

种植基台-软组织牢固的生物学封闭与种植基台-种植体稳定的机械连接是种植修复良好功能和美学的基础。种植基台表面污染会对该生物学封闭和机械连接造成不利影响,然而适用于义齿加工厂的种植基台的清洗、消毒和灭菌方法目前尚无共识。本文将对研究义齿加工厂加工上部修复体后出厂的种植基台的表面污染现状、影响及其清洗、消毒和灭菌方法的相关文献研究进行综述,以期为义齿加工厂建立种植基台的出厂前标准卫生处理程序提供参考。

关键词: 种植基台, 表面污染, 并发症, 清洗, 消毒, 灭菌

Abstract:

The biological integration of implant abutments with soft tissues and the stable mechanical connection between the implant and abutment are fundamental to the optimal function and aesthetics of implant restorations. Surface contamination of implant abutments may compromise their biological integration and mechanical stability. However, no consensus has been reached regarding the cleaning, disinfection, and sterilization methods for implant abutments in dental laboratory settings. This work aims to review the literature on the prevalence and implications of surface contamination on implant abutments supplied by dental laboratories. Cleaning, disinfection, and sterilization methods for implant abutments are also assessed. The objective is to inform the development of standardized predelivery hygiene protocols for implant abutments within the dental laboratory workflow.

Key words: implant abutment, surface contamination, complication, cleaning, disinfection, sterilization

中图分类号: 

  • R78
[1] Alghamdi HS, Jansen JA. The development and future of dental implants[J]. Dent Mater J, 2020, 39(2): 167-172.
[2] Lee JH, Lee JB, Kim MY, et al. Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional implant prosthetic system[J]. J Adv Prosthodont, 2016, 8(2): 150-157.
[3] Ju CM, Lee Y, Hong SJ, et al. Risk factors associa-ted with screw loosening in CAD-CAM custom abutments: a 6-year retrospective study[J]. J Prosthet Dent, 2025, 133(5): 1235-1241.
[4] Yi Y, Koak JY, Kim SK, et al. Comparison of implant component fractures in external and internal type: a 12-year retrospective study[J]. J Adv Pros-thodont, 2018, 10(2): 155-162.
[5] Apaza-Bedoya K, Galarraga-Vinueza ME, Correa BB, et al. Prevalence, risk indicators, and clinical characteristics of peri-implant mucositis and peri-implantitis for an internal conical connection implant system: a multicenter cross-sectional study[J]. J Periodontol, 2024, 95(6): 582-593.
[6] Rakic M, Galindo-Moreno P, Monje A, et al. How frequent does peri-implantitis occur-a systematic review and meta-analysis[J]. Clin Oral Investig, 2018, 22(4): 1805-1816.
[7] Murakami H, Igarashi K, Fuse M, et al. Risk factors for abutment and implant fracture after loading[J]. J Oral Sci, 2021, 63(1): 92-97.
[8] Soulami S, Slot DE, van der Weijden F. Implant-abutment emergence angle and profile in relation to peri-implantitis: a systematic review[J]. Clin Exp Dent Res, 2022, 8(4): 795-806.
[9] Gehrke P, Riebe O, Fischer C, et al. Microbiological cleaning and disinfection efficacy of a three-stage ultrasonic processing protocol for CAD-CAM implant abutments[J]. J Adv Prosthodont, 2022, 14(5): 273-284.
[10] Borie M, Lambert F, Lecloux G, et al. Peri-implant soft tissue integration in humans-influence of materials: a study protocol for a randomised controlled trial and a pilot study results[J]. Contemp Clin Trials Commun, 2020, 19: 100643.
[11] Rutkunas V, Borusevicius R, Liaudanskaite D, et al. The effect of different cleaning protocols of polymer-based prosthetic materials on the behavior of human gingival fibroblasts[J]. Int J Environ Res Public Health, 2020, 17(21): 7753.
[12] Avila-Ortiz G, Gonzalez-Martin O, Couso-Queiruga E, et al. The peri-implant phenotype[J]. J Periodontol, 2020, 91(3): 283-288.
[13] Homayouni A, Bahador A, Moharrami M, et al. Effect of 5 popular disinfection methods on microflora of laboratory: customized implant abutments[J]. Implant Dent, 2019, 28(5): 437-446.
[14] 国家卫生和计划生育委员会. 口腔器械消毒灭菌技术操作规范: [S]. 北京: 中国标准出版社, 2017.
National Health and Family Planning Commission. Regulation for disinfection and sterilization technique of dental instruments: [S]. Beijing: Standards Press of China, 2017.
[15] Processing of health care products-information to be provided by the medical device manufacturer for the processing of medical devices: [S]. Geneva: International Organization for Standardization, 2017.
[16] Yin LN, Zhu YB, Yu HJ, et al. Evaluating the efficiency of three methods to clean and disinfect screw- and cement-retained prostheses[J]. J Prosthet Dent, 2022, 127(5): 775-782.
[17] 施斌, 曾浩. 种植修复基台的选择[J]. 华西口腔医学杂志, 2017, 35(2): 124-126.
Shi B, Zeng H. Selection of abutment for implant restoration[J]. West China J Stomatol, 2017, 35(2): 124-126.
[18] Sharon E, Pietrokovski Y, Engel I, et al. Biocompatibility, surface morphology, and bacterial load of dental implant abutments following decontamination protocols: an in-vitro study[J]. Materials, 2023, 16(11): 4080.
[19] Gehrke P, Abazari C, Schlichter K, et al. Qualitative and semi-quantitative assessment of processing-related surface contamination of one- and two-piece CAD/CAM abutments before and after ultrasonic cleaning[J]. Materials, 2020, 13(14): 3225.
[20] Kim S, Choi C, Cha YS, et al. The efficacy of convenient cleaning methods applicable for customized abutments: an in vitro study[J]. BMC Oral Health, 2021, 21(1): 78.
[21] Nakajima K, Odatsu T, Shinohara A, et al. Effects of cleaning methods for custom abutment surfaces on gene expression of human gingival fibroblasts[J]. J Oral Sci, 2017, 59(4): 533-539.
[22] Leong SS, Korel F, King JH. Bacillus cereus: a review of “fried rice syndrome” causative agents[J]. Microb Pathog, 2023, 185: 106418.
[23] Veras EL, dos Santos NC, Souza JGS, et al. Newly identified pathogens in periodontitis: evidence from an association and an elimination study[J]. J Oral Microbiol, 2023, 15(1): 2213111.
[24] Canullo L, Micarelli C, Iannello G. Microscopical and chemical surface characterization of the gingival portion and connection of an internal hexagon abutment before and after different technical stages of preparation[J]. Clin Oral Implants Res, 2013, 24(6): 606-611.
[25] Canullo L, Micarelli C, Lembo-Fazio L, et al. Microscopical and microbiologic characterization of customized titanium abutments after different clea-ning procedures[J]. Clin Oral Implants Res, 2014, 25(3): 328-336.
[26] Canullo L, Tallarico M, Chu S, et al. Cleaning, disinfection, and sterilization protocols employed for customized implant abutments: an international survey of 100 universities worldwide[J]. Int J Oral Maxillofac Implants, 2017, 32(4): 774-778.
[27] Corvino E, Pesce P, Mura R, et al. Influence of mo-dified titanium abutment surface on peri-implant soft tissue behavior: a systematic review of in vitro studies[J]. Int J Oral Maxillofac Implants, 2020, 35(3): 503-519.
[28] Pesce P, Menini M, Tommasato G, et al. Influence of modified titanium abutment surface on peri-implant soft tissue behaviour: a systematic review of histological findings[J]. Int J Oral Implantol (Berl), 2019, 12(4): 419-429.
[29] Ulusoy HÖ, Ercan E, Özatik O, et al. Fibrin clot adherence on cleaned and decontaminated titanium abutment surfaces: an in vitro study[J]. Clin Implant Dent Rel Res, 2024, 26(6): 1190-1199.
[30] Lacey DC, De Kok B, Clanchy FI, et al. Low dose metal particles can induce monocyte/macrophage survival[J]. J Orthop Res, 2009, 27(11): 1481-1486.
[31] Yang S-Y, Zhang K, Bai L, et al. Polymethylmetha-crylate and titanium alloy particles activate periphe-ral monocytes during periprosthetic inflammation and osteolysis[J]. J Orthop Res, 2011, 29(5): 781-786.
[32] Toledano-Serrabona J, Bosch BM, Díez-Tercero L, et al. Evaluation of the inflammatory and osteogenic response induced by titanium particles released du-ring implantoplasty of dental implants[J]. Sci Rep, 2022, 12: 15790.
[33] Ivanovski S, Lee R. Comparison of peri-implant and periodontal marginal soft tissues in health and di-sease[J]. Periodontol 2000, 2018, 76(1): 116-130.
[34] Shemtov-Yona K, Arieli A, Barhum M, et al. The effect of contaminating media on the static and dynamic mechanical resilience of dental implant abutments’ screws: in vitro study[J]. Clin Implant Dent Rel Res, 2024, 26(2): 289-298.
[35] Micarelli C, Canullo L, Baldissara P, et al. Implant abutment screw reverse torque values before and after plasma cleaning[J]. Int J Prosthodont, 2013, 26(4): 331-333.
[36] D’Ercole S, Dotta TC, Farani MR, et al. Bacterial microleakage at the implant-abutment interface: an in vitro study[J]. Bioengineering, 2022, 9(7): 277.
[37] Sasada Y, Cochran D. Implant-abutment connections: a review of biologic consequences and peri-implantitis implications[J]. Int J Oral Maxillofac Implants, 2017, 32(6): 1296-1307.
[38] Canullo L, Dehner JF, Penarrocha D, et al. Soft tissue response to titanium abutments with different surface treatment: preliminary histologic report of a randomized controlled trial[J]. Biomed Res Int, 2016, 2016: 2952530.
[39] Canullo L, Penarrocha-Oltra D, Marchionni S, et al. Soft tissue cell adhesion to titanium abutments after different cleaning procedures: preliminary results of a randomized clinical trial[J]. Med Oral, 2014: e177-e183.
[40] Farronato D, Fumagalli D, Asa’ad F, et al. Decontamination of customized laser-microtextured tita-nium abutments: a comparative in vitro study of different cleaning procedures[J]. Int J Periodontics Restorative Dent, 2018, 38(5): e87-e95.
[41] Linkevicius T, Gineviciute E, Alkimavicius J, et al. Comparison of different cleaning procedures for decontaminating zirconium oxide surface after poli-shing[J]. Int J Prosthodont, 2023, 36(5): 588-594.
[42] Gehrke P, Smeets R, Gosau M, et al. The influence of an ultrasonic cleaning protocol for CAD/CAM abutment surfaces on cell viability and inflammatory response in vitro [J]. In Vivo, 2019, 33(3): 689-698.
[43] Sarfaraz H, Netalkar PP, Shetty M, et al. Decontaminating the surfaces of bonded screw-retained implant prostheses: a comparison of three different post-processing cleaning techniques[J]. J Prosthet Dent, 2025, 133(2): 541.e1-541.e6.
[44] Al-Saleh S. Efficacy of contemporary agents on disinfection and surface roughness of polyetheretherketone implant abutments[J]. Photodiagn Photodyn Ther, 2022, 38: 102798.
[45] Behr M, Schneider-Feyrer S, Huber C, et al. The effect of sterilization and ultrasonic cleaning on resin cement interface of customized dental implant abutments[J]. J Mech Behav Biomed Mater, 2020, 104: 103660.
[46] 中华人民共和国卫生部. 医疗机构消毒技术规范: [S]. 北京: 中国标准出版社, 2012.
Ministry of Health of the People’s Republic of China. Regulation of disinfection technique in healthcare settings: [S]. Beijing: Standards Press of China, 2012.
[47] Matthes R, Jablonowski L, Holtfreter B, et al. Fibroblast growth on zirconia ceramic and titanium disks after application with cold atmospheric pressure plasma devices or with antiseptics[J]. Int J Oral Maxillofac Implants, 2019, 34(4): 809-818.
[48] Canullo L, Tallarico M, Penarrocha M, et al. Plasma of argon cleaning treatment on implant abutments in periodontally healthy patients: six years postloading results of a randomized controlled trial[J]. Int J Pe-riodontics Restorative Dent, 2017, 37(5): 683-690.
[49] Canullo L, Penarrocha D, Micarelli C, et al. Hard tissue response to argon plasma cleaning/sterilisation of customised titanium abutments versus 5-se-cond steam cleaning: results of a 2-year post-loading follow-up from an explanatory randomised controlled trial in periodontally healthy patients[J]. Eur J Oral Implantol, 2013, 6(3): 251-260.
[50] Canullo L, Peñarrocha D, Clementini M, et al. Impact of plasma of argon cleaning treatment on implant abutments in patients with a history of pe-riodontal disease and thin biotype: radiographic results at 24-month follow-up of a RCT[J]. Clin Oral Implants Res, 2015, 26(1): 8-14.
[51] Canullo L, Tallarico M, Peñarrocha-Oltra D, et al. Implant abutment cleaning by plasma of argon: 5-year follow-up of a randomized controlled trial[J]. J Periodontol, 2016, 87(4): 434-442.
[52] Canullo L, Masucci L, Quaranta G, et al. Culturomic and quantitative real-time-polymerase chain reaction analyses for early contamination of abutments with different surfaces: a randomized clinical trial[J]. Clin Implant Dent Relat Res, 2021, 23(4): 568-578.
[53] Carossa M, Cavagnetto D, Mancini F, et al. Plasma of argon treatment of the implant surface, systema-tic review of in vitro studies[J]. Biomolecules, 2022, 12(9): 1219.
[54] Mehl C, Kern M, Zimmermann A, et al. Impact of cleaning procedures on adhesion of living cells to three abutment materials[J]. Int J Oral Maxillofac Implants, 2017, 32(5): 976-984.
[55] Ortega-Llamas L, Quiñones-Vico MI, García-Val- divia M, et al. Cytotoxicity and wound closure eva-luation in skin cell lines after treatment with common antiseptics for clinical use[J]. Cells, 2022, 11(9): 1395.
[56] Furuya K, Takemoto S, Yamashita S, et al. Low-temperature degradation of high-strength Y-TZP (yttria-stabilized tetragonal zirconia polycrystal) [J]. Dent Mater J, 2020, 39(4): 577-586.
[57] Lang R, Hiller KA, Kienböck L, et al. Influence of autoclave sterilization on bond strength between zirconia frameworks and Ti-base abutments using different resin cements[J]. J Prosthet Dent, 2022, 127(4): 617.e1-617.e6.
[58] Pils D, Baeppler RJ, Junker R, et al. Application of a standard autoclaving protocol does not harm structural integrity of two-piece zirconia abutments under detachment force testing[J]. Clin Oral Investig, 2019, 23(7): 3133-3137.
[59] Wiedenmann F, Liebermann A, Spintzyk S, et al. Influence of different cleaning procedures on tensile bond strength between zirconia abutment and tita-nium base[J]. Int J Oral Maxillofac Implants, 2019, 34(6): 1318-1327.
[60] Gehrke P, Tabellion A, Fischer C. Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis[J]. J Adv Prosthodont, 2015, 7(2): 151-159.
[61] Hofmann P, Kunz A, Schmidt F, et al. Influence of exposure of customized dental implant abutments to different cleaning procedures: an in vitro study u-sing AI-assisted SEM/EDS analysis[J]. Int J Implant Dent, 2023, 9(1): 33.
[1] 张红,俞青. 种植基台几何形状对氧化锆冠轴向固位力的影响[J]. 国际口腔医学杂志, 2025, 52(5): 621-626.
[2] 潘珮玥,周婧,黄超,于乐,唐甜. 埋伏牙正畸治疗的研究进展[J]. 国际口腔医学杂志, 2024, 51(6): 669-676.
[3] 高丽钞,刘畅,刘云通,罗瑜雪,曹钰彬,华成舸. 拔牙术后舌神经功能障碍的诊治进展[J]. 国际口腔医学杂志, 2024, 51(4): 489-497.
[4] Huangphattarakul Vicha,满毅. 上颌窦提升中上颌窦黏骨膜穿孔的研究进展[J]. 国际口腔医学杂志, 2023, 50(5): 552-557.
[5] 王仁义,赵呈智,潘剑. 拔牙围手术期预防性使用抗生素对术后并发症影响的研究进展[J]. 国际口腔医学杂志, 2023, 50(5): 558-565.
[6] 李春洁, 毕小琴, 朱桂全. 口腔颌面部肿瘤患者游离皮瓣修复术的并发症预防及处理[J]. 国际口腔医学杂志, 2023, 50(2): 127-137.
[7] 李转转,格根塔娜. 牙髓血运重建术根管冲洗消毒药物的研究进展[J]. 国际口腔医学杂志, 2022, 49(5): 569-577.
[8] 林洁,刘帆. 基于多酶清洗剂控制的口腔专科器械清洗消毒模式的探索[J]. 国际口腔医学杂志, 2022, 49(3): 324-327.
[9] 沈冬妮,施莹,傅柏平. 后牙牙合贴面修复的研究进展[J]. 国际口腔医学杂志, 2021, 48(3): 287-291.
[10] 谭凯璇,李帆,张利娟,李姗姗,卢洁,张颖,杨芳. 根管再治疗并发皮下气肿1例[J]. 国际口腔医学杂志, 2020, 47(5): 563-566.
[11] 唐蓓,赵文俊,王虎,郑广宁,游梦. 根管超填导致下牙槽神经损伤2例[J]. 国际口腔医学杂志, 2020, 47(3): 293-296.
[12] 付栩楠,谢志刚. 种植固定修复中基台机械并发症的研究进展[J]. 国际口腔医学杂志, 2019, 46(5): 571-577.
[13] 黄丽东, 宫玮玉, 董艳梅. 根管冲洗的研究进展[J]. 国际口腔医学杂志, 2018, 45(4): 465-472.
[14] 贾卓群, 杨路. 影响根管消毒剂氢氧化钙清除效率的因素[J]. 国际口腔医学杂志, 2018, 45(4): 439-443.
[15] 李韶容, 张茹, 侯本祥. 根管用药对牙齿力学性能的影响[J]. 国际口腔医学杂志, 2017, 44(3): 273-278.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!