Inter J Stomatol ›› 2015, Vol. 42 ›› Issue (6): 659-663.doi: 10.7518/gjkq.2015.06.011

Previous Articles     Next Articles

Safe region of micro-implant used for orthodontic anchorage positioning in the posterior maxillary alveolar bone

Zhao Jingzi1, Zhang Wenjun2, Zhang Xiaodong2.   

  1. 1. Dept. of Orthodontics, East Hospital District, Jinan Stomatology Hospital, Jinan 250013, China; 2. Dept. of Stomatology, The General Hospital of Shenyang Military Region, Shenyang 110840, China
  • Received:2015-01-26 Revised:2015-06-12 Online:2015-11-01 Published:2015-11-01

Abstract:

Objective This study aimed to measure the distance between a tooth and a soft tissue. This study also aimed to determine the safe region of micro-implant for orthodontic anchorage positioning in the posterior maxillary alveolar bone. Methods Twenty-one cone beam computed tomography reconstruction images of the craniofacial bone of preorthodontic patients were used in this research. Both sides of the mesiodistal distance of the two adjacent teeth in the posterior maxillary alveolar bone were measured at 6, 8, 10, 12, 14, and 16 mm from the horizontal plane. A vernier caliper was used to measure the clinical crown height of the posterior maxillary teeth in the plaster maxillary dentition model. A periodontal probe along the long axis of a tooth was used to determine the width of the free gingiva and the width from the gingival margin to the mucogingival junction. Results In the posterior area of the maxilla, the widest mesiodistal distance of tooth roots was between the second premolar and the first molar. Among the teeth, the maxillary first premolar yielded the highest crown height. The maxillary second molar region showed the widest attached gingiva. Conclusion The safe region of the micro-implant is located in the second premolar and the first molar; the vertical distance from the horizontal plane is 10-11 mm.

Key words: micro-implant, safe region, anchorage

CLC Number: 

  • R 783.5

TrendMD: 
[1] Zhu Yeling,Wang Xi,Sun Tiantong,Wang Lina,He Xiaoming,Li Jiazhi. Improved application of a novel device that could achieve dental arch mesialization [J]. Int J Stomatol, 2023, 50(1): 82-90.
[2] Zhang Shizhen,Lai Wenli. Research progress on maxillary protraction methods and auxiliary maxillary expansion for skeletal Class Ⅲ malocclusion [J]. Int J Stomatol, 2021, 48(3): 354-361.
[3] Tian Qinglu,Zhao Zhihe. Research progress on stability of mini-implants in orthodontic treatments [J]. Int J Stomatol, 2020, 47(2): 212-218.
[4] Yan Dan,Zhang Xizhong,Wang Jianguo. 3D finite element analysis for influence of microimplant thread depth on microimplant and mandible [J]. Int J Stomatol, 2019, 46(4): 387-392.
[5] Yanli Liu,Wei Zhao,Biying Zhang,Xiaoli An. Research progress on maxillary protraction with skeletal anchorage in growing patients with Class Ⅲ malocclusion [J]. Inter J Stomatol, 2019, 46(1): 112-118.
[6] Zeng Tingyan, Huang Shenggao. A three-dimensional finite element analysis for stability of mini-implant anchorage [J]. Inter J Stomatol, 2018, 45(1): 112-118.
[7] Yan Dan, Zhang Xizhong, Wang Zengquan, Wang Jianguo, Guan Zejian. Three-dimensional finite element analysis for the influence of micro-implant pitch on micro-implant-bone interface [J]. Inter J Stomatol, 2015, 42(5): 557-561.
[8] Wang Qiaojing, Huang Zhenxian, Xiao Liwei. Research progress on mini-implant displacement under orthodontic loading [J]. Inter J Stomatol, 2015, 42(5): 572-574.
[9] Wen Xingtao1, Ren Bolin1, Bao Lina2, Li Dongjian1. Clinical study of traction preservation of maxillary anterior teeth residual root with microscrew anchorage [J]. Inter J Stomatol, 2015, 42(4): 426-429.
[10] Xie Yufei, Lu Peijun, Hu Zheng, Feng Jing, Shen Gang. Cone beam computed tomography analysis on the cortical bone thickness of infrazygomatic crest [J]. Inter J Stomatol, 2014, 41(3): 281-285.
[11] He Han, He Hong.. Clinical application of implant anchorage for vertical control in orthodontics [J]. Inter J Stomatol, 2013, 40(5): 648-652.
[12] Li Xue, Feng Xiaoxia, Zhao Zhihe.. The negative effects of miniscrew anchorage in clinical application [J]. Inter J Stomatol, 2013, 40(4): 493-495.
[13] Li Jianhua, Feng Xiaoxia, Yang Pu. Research progress on the bone-anchored maxillary protraction [J]. Inter J Stomatol, 2013, 40(3): 416-418.
[14] Wang Yanan, Yang Siwei..
The clinical and basic research of mini -implant anchorage for the anterior teeth intrusion
[J]. Inter J Stomatol, 2013, 40(2): 221-223.
[15] Zhang Mengjie, Sun Yingming, Wang Xiaobo, Zhang Jiayu.. A preliminary study on accurate placement of orthodontic miniscrew [J]. Inter J Stomatol, 2011, 38(5): 527-530.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] . [J]. Foreign Med Sci: Stomatol, 1999, 26(06): .
[2] . [J]. Foreign Med Sci: Stomatol, 1999, 26(06): .
[3] . [J]. Foreign Med Sci: Stomatol, 1999, 26(05): .
[4] . [J]. Foreign Med Sci: Stomatol, 1999, 26(05): .
[5] . [J]. Foreign Med Sci: Stomatol, 1999, 26(05): .
[6] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .
[7] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .
[8] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .
[9] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .
[10] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .