Inter J Stomatol ›› 2019, Vol. 46 ›› Issue (2): 166-170.doi: 10.7518/gjkq.2019013

• Periodontal Diseases • Previous Articles     Next Articles

Research progress on the influence of removable clear aligners on periodontal health

Xu Feng,Yi Zhang,Menghong Li,Nan Liu,Liuyi Wang,Min. Hu()   

  1. Dept. of Orthodontics, Hospital of Stomatology, Jilin University, Changchun 130021, China
  • Received:2018-06-13 Revised:2018-12-10 Online:2019-03-01 Published:2019-03-15
  • Contact: Min. Hu E-mail:humin@jlu.edu.cn
  • Supported by:
    This study was supported by National Natural Science Foundation of China(81470764)

Abstract:

As a new method of orthodontic treatment, removable clear aligners have the advantages of comfort, esthetic results, and removable property compared with the traditional fixed orthodontic appliances. However, given that this aligner needs to be worn for extended periods a day, the interference on the oral self-cleaning action may accumulate both food residue and dental plaque, thereby aggravating the periodontal inflammation and damaging the periodontal health. In this paper, the effects of the material properties of removable clear aligners and microbial factors on periodontal health and the effect on clinical periodontal index are reviewed.

Key words: removable clear aligners, microflora of oral, periodontal index, bacterial adhesion

CLC Number: 

  • R783.5

TrendMD: 
[1] Clements KM, Bollen AM, Huang G , et al. Activa-tion time and material stiffness of sequential removable orthodontic appliances. Part 2: dental improvements[J]. Am J Orthod Dentofacial Orthop, 2003,124(5):502-508.
doi: 10.1016/S0889-5406(03)00577-8
[2] Gerard Bradley T, Teske L, Eliades G , et al. Do the mechanical and chemical properties of Invisalign TM appliances change after use? A retrieval analysis [J]. Eur J Orthod, 2016,38(1):27-31.
doi: 10.1093/ejo/cjv003 pmid: 25740599
[3] Lombardo L, Arreghini A, Maccarrone R , et al. Optical properties of orthodontic aligners—spectrophotometry analysis of three types before and after aging[J]. Prog Orthod, 2015,16:41.
doi: 10.1186/s40510-015-0111-z pmid: 4651973
[4] Gracco A, Mazzoli A, Favoni O , et al. Short-term chemical and physical changes in invisalign appliances[J]. Aust Orthod J, 2009,25(1):34-40.
pmid: 19634462
[5] 郑赛男, 蒋丽, 李伟 . 口腔细菌黏附机制的研究进展[J]. 国际口腔医学杂志, 2016,43(2):223-227.
doi: 10.7518/gjkq.2016.02.024
Zheng SN, Jiang L, Li W . Research progress on oral bacterial adhesion mechanism[J]. Int J Stomatol, 2016,43(2):223-227.
doi: 10.7518/gjkq.2016.02.024
[6] Eliades T, Pratsinis H, Athanasiou AE , et al. Cytoto-xicity and estrogenicity of Invisalign appliances[J]. Am J Orthod Dentofacial Orthop, 2009,136(1):100-103.
doi: 10.1016/j.ajodo.2009.03.006 pmid: 19577155
[7] Awosika O, Kao S, Rengifo-Pardo M , et al. Angioe-dema, stomatitis, and urticaria caused by contact allergy to invisalign[J]. Dermatitis, 2017,28(5):323-324.
doi: 10.1097/DER.0000000000000314 pmid: 28885312
[8] Premaraj T, Simet S, Beatty M , et al. Oral epithelial cell reaction after exposure to Invisalign plastic ma-terial[J]. Am J Orthod Dentofacial Orthop, 2014,145(1):64-71.
doi: 10.1016/j.ajodo.2013.09.011 pmid: 24373656
[9] Gomes SC, Varela CC, da Veiga SL , et al Periodontal conditions in subjects following orthodontic therapy. A preliminary study[J]. Eur J Orthod, 2007,29(5):477-481.
doi: 10.1093/ejo/cjm050 pmid: 17693428
[10] Kaygisiz E, Uzuner FD, Yuksel S , et al. Effects of self-ligating and conventional brackets on halitosis and periodontal conditions[J]. Angle Orthod, 2015,85(3):468-473.
doi: 10.2319/041714-289.1 pmid: 25101909
[11] Boke F, Akkaya S, Akkaya M , et al. Relationship between orthodontic treatment and gingival health: a retrospective study[J]. Eur J Dent, 2014,8(3):373-380.
doi: 10.4103/1305-7456.137651
[12] Al-Anezi SA . Dental plaque associated with self-ligating brackets during the initial phase of ortho-dontic treatment: a 3-month preliminary study[J]. J Orthod Sci, 2014,3(1):7-11.
doi: 10.4103/2278-0203.127550 pmid: 4072391
[13] Low B, Lee W, Seneviratne CJ , et al. Ultrastructure and morphology of biofilms on thermoplastic ortho-dontic appliances in ‘fast’ and ‘slow’ plaque formers[J]. Eur J Orthod, 2011,33(5):577-583.
doi: 10.1093/ejo/cjq126 pmid: 21187528
[14] Shpack N, Greenstein RB, Vardimon A . RE: response to: efficacy of three hygienic protocols in reducing biofilm adherence to removable thermoplastic ap-pliance. The Angle Orthodontist 2014(1) 161-170[J]. Angle Orthod, 2014,84(3):574.
doi: 10.2319/0003-3219-84.3.574 pmid: 24749708
[15] Schuster S, Eliades G, Zinelis S , et al. Structural conformation and leaching from in vitro aged and retrieved Invisalign appliances[J]. Am J Orthod Dentofacial Orthop, 2004,126(6):725-728.
doi: 10.1016/j.ajodo.2004.04.021 pmid: 15592222
[16] Verran J, Jackson S, Coulthwaite L , et al. The effect of dentifrice abrasion on denture topography and the subsequent retention of microorganisms on abraded surfaces[J]. J Prosthet Dent, 2014,112(6):1513-1522.
doi: 10.1016/j.prosdent.2014.05.009 pmid: 24998324
[17] Levrini L, Mangano A, Margherini S , et al. ATP bio-luminometers analysis on the surfaces of removable orthodontic aligners after the use of different cleaning methods[J]. Int J Dent, 2016,2016:5926941.
doi: 10.1155/2016/5926941 pmid: 4875988
[18] Levrini L, Novara F, Margherini S , et al. Scanning electron microscopy analysis of the growth of dental plaque on the surfaces of removable orthodontic aligners after the use of different cleaning methods[J]. Clin Cosmet Investig Dent, 2015,7:125-131.
doi: 10.2147/CCIDE.S95814 pmid: 4687621
[19] Cruz PC, Andrade IM, Peracini A , et al. The effec-tiveness of chemical denture cleansers and ultrasonic device in biofilm removal from complete dentures[J]. J Appl Oral Sci, 2011,19(6):668-673.
doi: 10.1590/S1678-77572011000600021 pmid: 22231005
[20] Nishi Y, Seto K, Kamashita Y , et al. Examination of denture-cleaning methods based on the quantity of microorganisms adhering to a denture[J]. Gerodonto-logy, 2012,29(2):e259-e266.
doi: 10.1111/j.1741-2358.2011.00461.x pmid: 21284712
[21] Paranhos HF, Silva-Lovato CH, Souza RF , et al. Effects of mechanical and chemical methods on denture biofilm accumulation[J]. J Oral Rehabil, 2007,34(8):606-612.
doi: 10.1111/j.1365-2842.2007.01753.x pmid: 17650171
[22] Sesma N, Rocha AL, Laganá DC , et al. Effectiveness of denture cleanser associated with microwave disin-fection and brushing of complete dentures: in vivo study[J]. Braz Dent J, 2013,24(4):357-361.
doi: 10.1590/0103-6440201302205 pmid: 24173256
[23] Perinetti G, Paolantonio M, Serra E , et al. Longitu-dinal monitoring of subgingival colonization by Ac-tinobacillus actinomycetemcomitans, and crevicular alkaline phosphatase and aspartate aminotransferase activities around orthodontically treated teeth[J]. J Clin Periodontol, 2004,31(1):60-67.
doi: 10.1111/j.0303-6979.2004.00450.x pmid: 15058376
[24] Kim SH, Choi DS, Jang I , et al. Microbiologic changes in subgingival plaque before and during the early period of orthodontic treatment[J]. Angle Orthod, 2012,82(2):254-260.
doi: 10.2319/030311-156.1 pmid: 21827233
[25] Levrini L, Mangano A, Montanari P , et al. Periodontal health status in patients treated with the Invisalign® system and fixed orthodontic appliances: a 3 months clinical and microbiological evaluation[J]. Eur J Dent, 2015,9(3):404-410.
doi: 10.4103/1305-7456.163218
[26] 石晶, 闫征斌, 侯景秋 , 等. 无托槽隐形矫治与传统固定矫治对牙周变异链球菌和牙龈卟啉单胞菌的影响[J]. 国际口腔医学杂志, 2016,43(2):151-154.
doi: 10.7518/gjkq.2016.02.008
Shi J, Yan ZB, Hou JQ , et al. Influence of bracketless invisible aligner technique and conventional te-chnique on the number of Streptococcus mutans and Porphyromonas gingivalis[J]. Int J Stomatol, 2016,43(2):151-154.
doi: 10.7518/gjkq.2016.02.008
[27] Karkhanechi M, Chow D, Sipkin J , et al. Periodontal status of adult patients treated with fixed buccal ap-pliances and removable aligners over one year of active orthodontic therapy[J]. Angle Orthod, 2013,83(1):146-151.
doi: 10.2319/031212-217.1 pmid: 22725616
[28] Miethke RR, Brauner K . A comparison of the perio-dontal health of patients during treatment with the Invisalign system and with fixed lingual appliances[J]. J Orofac Orthop, 2007,68(3):223-231.
doi: 10.1007/s00056-005-0436-1 pmid: 17522806
[29] Miethke RR, Vogt S . A comparison of the periodontal health of patients during treatment with the Invisa-lign system and with fixed orthodontic appliances[J]. J Orofac Orthop, 2005,66(3):219-229.
doi: 10.1007/s00056-005-0436-1 pmid: 17522806
[30] Rossini G, Parrini S, Castroflorio T , et al. Periodontal health during clear aligners treatment: a systematic review[J]. Eur J Orthod, 2015,37(5):539-543.
doi: 10.1093/ejo/cju083 pmid: 25548145
[31] 周少丽, 郭泾 . 无托槽隐形矫治技术与传统固定矫治技术对患者牙周健康影响的对比研究[J]. 国际口腔医学杂志, 2013,40(2):172-175.
doi: 10.7518/gjkq.2013.02.010
Zhou SL, Guo J . Comparison of periodontal health of patients during treatment with the invisalign system and with fixed orthodontic appliance[J]. Int J Stomatol, 2013,40(2):172-175.
doi: 10.7518/gjkq.2013.02.010
[32] 李伟, 黄玉婷 . 无托槽隐形矫治器与传统固定矫治器对患者牙周健康影响的临床观察[J]. 实用口腔医学杂志, 2017,33(2):270-272.
Li W, Huang YT . Comparation of periodontal health of patients treated by the invisalign system with those treated by fixed orthodontic appliance[J]. J Pract Stomatol, 2017,33(2):270-272.
[33] 李炎钊, 谭家莉 . 无托槽隐形矫治器与固定矫治器对牙周健康影响的纵向临床观察[J]. 临床口腔医学杂志, 2015,31(8):486-488.
doi: 10.3969/j.issn.1003-1634.2015.08.013
Li YZ, Tan JL . Effects on periodontal health in the use of the invisalign and fixed appliance: a longitu-dinal comparative study in clinic[J]. J Clin Stomatol, 2015,31(8):486-488.
doi: 10.3969/j.issn.1003-1634.2015.08.013
[34] 张玉峰, 罗三莲, 郑纪伟 , 等. 无托槽隐形矫治器与直丝弓矫治器对成人牙周炎继发错畸形矫治效果的对比研究[J]. 临床口腔医学杂志, 2015,31(10):617-619.
doi: 10.3969/j.issn.1003-1634.2015.10.016
Zhang YF, Luo SL, Zheng JW , et al. Comparison of effect of patients with malocclusion induced by adult periodontitis after treatment with bracket-less invisible appliance and straight wire appliance[J]. J Clin Sto-matol, 2015,31(10):617-619.
doi: 10.3969/j.issn.1003-1634.2015.10.016
[35] Boas Nogueira AV , Chaves de Souza JA, Kim YJ, et al. Orthodontic force increases interleukin-1β and tumor necrosis factor-α expression and alveolar bone loss in periodontitis[J]. J Periodontol, 2013,84(9):1319-1326.
doi: 10.1902/jop.2012.120510 pmid: 23205916
[1] Wang Rui,Gai Kuo,Liu Mengqi,Jiang Li. Role of atomic force microscopy in research on microbial adhesion force [J]. Int J Stomatol, 2019, 46(6): 687-692.
[2] Mengqi Liu,Kuo Gai,Li Jiang. Research progress on oral implant materials with antimicrobial properties [J]. Inter J Stomatol, 2018, 45(5): 516-521.
[3] Huang Haixia, Lan Yuyan, Zhang Hao, Pan Lanlan, Guo Ling, Liu Min. Changes on periodontal index and inflammatory factor levels in gingival crevicular fluid after implant restoration in patients with chronic periodontitis [J]. Inter J Stomatol, 2018, 45(4): 396-402.
[4] Gai Kuo, Hao Liying, Jiang Li.. Study of the adhesion mechanism of oral Streptococcus mutans based on atomic force microscope [J]. Inter J Stomatol, 2017, 44(3): 320-324.
[5] Shi Jing1,2, Peng Hui1.. Clinical application status and prospects of self-ligating and conventional brackets on periodontal environments [J]. Inter J Stomatol, 2012, 39(6): 824-827.
[6] GUI He-ming, DU Li-juan, WANG Wei-wei, LEI Gong-yuan, LAN Qian, HUANG Jie-ying. Clinical study on treating serious periodontal disease by two sorts of therapy in [J]. Inter J Stomatol, 2009, 36(2): 133-133~136.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] . [J]. Foreign Med Sci: Stomatol, 1999, 26(06): .
[2] . [J]. Foreign Med Sci: Stomatol, 1999, 26(06): .
[3] . [J]. Foreign Med Sci: Stomatol, 1999, 26(05): .
[4] . [J]. Foreign Med Sci: Stomatol, 1999, 26(05): .
[5] . [J]. Foreign Med Sci: Stomatol, 1999, 26(05): .
[6] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .
[7] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .
[8] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .
[9] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .
[10] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .