Abstract:

Objective To change the composition of titanium surface, and improve the wear resistance. Methods Nitrogen was implanted into the surface of pure titanium using plasma ion implantation, the ion implantation dose was 3×1017 ions·cm-2 and 9×1017 ions·cm-2. The change of surface elements was analyzed by energy-dispersive spectrometry. The hardness of the treated samples was evaluated with micro-hardness tester. The wear resistance was measured by nano-scratch tester. The scratch morphology was analyzed by scanning electron microscope. Results The samples modified by plasma ion implantation showed light golden. The ion implantation dose of 3×1017 ions·cm-2 and 9×1017 ions·cm-2 nitrogen atom content of the samples were 24.08% and 35.83%. The hardness of samples after ion implantation was significantly greater than the samples before ion implantation. The friction coefficient of samples after ion implantation decreased significantly. Conclusion After nitrogen ion implantation, hardness increased significantly, wear resistance of pure titanium can also been improved.

Key words: pure titanium, plasma ion implantation, nano-scratch, micro-friction, wear mechanism


TrendMD: 
[1] Qing Ping,Gao Shanshan,Qian Linmao,Yu Haiyang. Microtribological behaviour of human tooth enamel treated by gamma irradiation [J]. Int J Stomatol, 2020, 47(2): 189-195.
[2] Wang Nan, Lian Yunmin,Gao Lan,Ma Xuemin. The inhibition of the organosilicon quaternary ammonium salt treated pure titanium to the Candida albicans [J]. Inter J Stomatol, 2017, 44(2): 175-178.
[3] Yuan Xiaohui, Liu Jie.. Research progress on the effect of micro-arc oxidation on the bonding strength between pure titanium and porcelain [J]. Inter J Stomatol, 2016, 43(6): 695-699.
[4] Sun Xu1, Zhai Junjiang2, Liao Jian2, Teng Minhua2, Huang He1, Guo Changjun1. Effects of hot hydrochloric acid combined with heating on titanium-ceramic bonding strength [J]. Inter J Stomatol, 2014, 41(5): 518-520.
[5] Zhang Qianqian1, Qiu Xiaoli2, Gao Shanshan1, Yu Haiyang1. Friction and wear behavior of two kinds of veneering porcelains in an acidic environment [J]. Inter J Stomatol, 2014, 41(3): 272-276.
[6] Gao Yu1, Wu Zhan’ao1, Feng Weizhong1, Ding Yan1, Zhang Deyun2, Jiang Tao1.. Effect of silicate solution in different concentrations on bonding strength of porcelain and pure titanium by liquid-phase deposition technology [J]. Inter J Stomatol, 2013, 40(4): 440-443.
[7] WU Lie, LUO Xiao- ping, SHU Cheng- jun.. Comparative research on fit of commercial pure titanium copings of different thickness [J]. Inter J Stomatol, 2007, 34(05): 328-330.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] . [J]. Foreign Med Sci: Stomatol, 1999, 26(06): .
[2] . [J]. Foreign Med Sci: Stomatol, 1999, 26(06): .
[3] . [J]. Foreign Med Sci: Stomatol, 1999, 26(06): .
[4] . [J]. Foreign Med Sci: Stomatol, 1999, 26(06): .
[5] . [J]. Foreign Med Sci: Stomatol, 1999, 26(05): .
[6] . [J]. Foreign Med Sci: Stomatol, 1999, 26(05): .
[7] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .
[8] . [J]. Foreign Med Sci: Stomatol, 1999, 26(04): .
[9] . [J]. Foreign Med Sci: Stomatol, 2004, 31(02): 126 -128 .
[10] . [J]. Inter J Stomatol, 2008, 35(S1): .