国际口腔医学杂志 ›› 2026, Vol. 53 ›› Issue (5): 711-718.doi: 10.7518/gjkq.2026623

• 综述 • 上一篇    

树脂-陶瓷复合材料在后牙区种植冠部修复应用的研究进展

陈思凡(),卓盈颖,陈姚,姜醒,郑志强,林捷()   

  1. 福建医科大学附属口腔医院特诊科 福州 350002
  • 收稿日期:2025-03-11 修回日期:2026-03-31 出版日期:2026-09-01 发布日期:2026-08-28
  • 通讯作者: 林捷
  • 作者简介:陈思凡,硕士,Email:645387152@qq.com
  • 基金资助:
    福建省自然科学基金(2023J01701)

Research progress on the application of resin-ceramic composites in crown restoration of posterior dental implants

Sifan Chen(),Yingying Zhuo,Yao Chen,Xing Jiang,Zhiqiang Zheng,Jie Lin()   

  1. Dept. of VIP Dental Service, School and Hospital of Stomatology, Fujian Medical University, Fuzhou 350002, China
  • Received:2025-03-11 Revised:2026-03-31 Online:2026-09-01 Published:2026-08-28
  • Contact: Jie Lin
  • Supported by:
    Fujian Province Natural Science Foundation(2023J01701)

摘要:

近年来树脂-陶瓷复合材料在后牙区种植冠修复中的应用逐步增多。本文综述了树脂-陶瓷复合材料的类型、力学性能和生物学特性,重点探讨其在种植修复中的基台设计和冠部形态优化等关键问题,分析该材料对种植体周围骨组织吸收的影响机制,并详细讨论表面处理技术和水门汀选择策略,为树脂-陶瓷复合材料在临床种植修复中的规范化应用提供理论依据和参考。

关键词: 树脂-陶瓷复合材料, 种植牙, 冠修复, 机械性能, 应力分布, 基台设计

Abstract:

In recent years, the application of resin‑ceramic composites in the restoration of implant-supported crowns in the posterior tooth region have been on the rise. This article comprehensively reviews the classification, mechanical properties, and biological characteristics of resin‑ceramic composites. It specifically delves into key aspects in implant restoration, such as the design of abutments and the optimization of crown morphology when using these materials. The mechanism by which resin‑ceramic composites affect the bone resorption around implants is analyzed in detail. Additionally, surface treatment techniques and strategies for selecting luting cements are elaborated. By summarizing current research findings, this review aims to provide a theoretical foundation and practical reference for the standardized application of resin‑ceramic composites in clinical implant restoration.

Key words: resin-ceramic composites, dental implants, crown restoration, mechanical property, stress distribution, abutment design

中图分类号: 

  • R783.4

表1

RCCs和传统牙科陶瓷的物理性能和成分比较"

材料类别代表产品厂家抗压强度/MPa抗弯强度/MPa单冠抗折力/N弹性模量/GPa泊松比化学成分
RCCsLAVA Ultimate3M ESPE516419842 48451260.37625%Bis-GMA、Bis-EMA、TEGDMA、UDMA,75%的SiO2和ZrO2填料7
Vita EnamicVITA Zahnfabrik370413141 95253760.24625%UDMA、TEGDMA,75%的铝硅酸盐玻璃填料7
氧化锆陶瓷LAVA plus3M ESPEN/A1 00786 065420590.1993 mol%Y2O3稳定的四方晶ZrO2陶瓷10
二硅酸锂陶瓷IPS e.max CADIvoclar Vivadent AGN/A30142 863510260.22611.0%~19.0%Li2O,0.0%~11.0%P2O5,0.0%~5.0%Al2O3,0.0%~13.0%K2O,57.0%~80.0%SiO2,其中晶相Li2Si2O5和Li3PO4占60%,非晶相占40%11
长石质陶瓷CEREC BlocsDentsply Sirona2021215413236545140.301456%~64%SiO2,20%~23%Al2O3,6%~9%Na2O,6%~8%K2O,0.3%~0.6%CaO,0%~0.1%TiO2,颜料<0.1%13
[1] Rosentritt M, Hahnel S, Engelhardt F, et al. In vitro performance and fracture resistance of CAD/CAM-fabricated implant supported molar crowns[J]. Clin Oral Invest, 2017, 21(4): 1213-1219.
[2] Capa N, Say EC, Celebi C, et al. Microtensile bond strengths of adhesively bonded polymer-based CAD/CAM materials to dentin[J]. Dent Mater J, 2019, 38(1): 75-85.
[3] Facenda JC, Borba M, Corazza PH. A literature review on the new polymer-infiltrated ceramic-network material (PICN)[J]. J Esthet Restor Dent, 2018, 30(4): 281-286.
[4] Elfadaly LS, Khairallah LS, Al Agroudy MA. Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study[J]. Int J Implant Dent, 2017, 3(1): 31.
[5] AlHelal AA. Biomechanical behavior of all-ceramic endocrowns fabricated using CAD/CAM: a syste-matic review[J]. J Prosthodont Res, 2024, 68(1): 50-62.
[6] Belli R, Wendler M, de Ligny D, et al. Chairside CAD/CAM materials. Part 1: measurement of elastic constants and microstructural characterization[J]. Dent Mater, 2017, 33(1): 84-98.
[7] Lubauer J, Belli R, Schünemann FH, et al. Inner marginal strength of CAD/CAM materials is not affected by machining protocol[J]. Biomater Investig Dent, 2021, 8(1): 119-128.
[8] Rosentritt M, Krifka S, Preis V, et al. Dynamic fatigue of composite CAD/CAM materials[J]. J Mech Behav Biomed Mater, 2019, 98: 311-316.
[9] D'Souza K, Aras M. Three-dimensional finite element analysis of the stress distribution pattern in a mandibular first molar tooth restored with five different restorative materials[J]. J Indian Prosthodont Soc, 2017, 17(1): 53.
[10] Gracis S, Thompson VP, Ferencz JL, et al. A new classification system for all-ceramic and ceramic-like restorative materials[J]. Int J Prosthodont, 2015, 28(3): 227-235.
[11] Vivadent Ivoclar. IPS e.max CAD[EB/OL]. [2021-04-14]. .
[12] 喻璐璐, 顾卫平. 三种椅旁CAD/CAM全瓷高嵌体的抗压强度[J]. 中国组织工程研究, 2018, 22(26): 4128-4132.
Yu LL, Gu WP. Compressive strength of three all-ceramic chairside CAD/CAM onlays[J]. Chin J Tiss Eng Res, 2018, 22(26): 4128-4132.
[13] Li Z, Zhu JX, Xu YX, et al. Biomechanical beha-viors of molars restored with endocrowns composed of different materials[J]. Materials, 2025, 18(2): 250.
[14] Švančárková A, Galusková D, Nowicka AE, et al. Effect of corrosive media on the chemical and mechanical resistance of IPS e.max® CAD based Li2Si2O5 glass-ceramics[J]. Materials (Basel), 2022, 15(1): 365.
[15] Ruse ND, Sadoun MJ. Resin-composite blocks for dental CAD/CAM applications[J]. J Dent Res, 2014, 93(12): 1232-1234.
[16] Mainjot AK, Dupont NM, Oudkerk JC, et al. From artisanal to CAD-CAM blocks: state of the art of indirect composites[J]. J Dent Res, 2016, 95(5): 487-495.
[17] Bergamo ETP, Yamaguchi S, Coelho PG, et al. Survival of implant-supported resin-matrix ceramic crowns: in silico and fatigue analyses[J]. Dent Mater, 2021, 37(3): 523-533.
[18] Schlenz MA, Schmidt A, Rehmann P, et al. Fatigue damage of monolithic posterior computer aided designed/computer aided manufactured crowns[J]. J Prosthodont Res, 2019, 63(3): 368-373.
[19] Swain MV, Coldea A, Bilkhair A, et al. Interpenetra-ting network ceramic-resin composite dental resto-rative materials[J]. Dent Mater, 2016, 32(1): 34-42.
[20] Nguyen JF, Ruse D, Phan AC, et al. High-temperature-pressure polymerized resin-infiltrated ceramic networks[J]. J Dent Res, 2014, 93(1): 62-67.
[21] Wendler M, Kaizer MR, Belli R, et al. Sliding contact wear and subsurface damage of CAD/CAM materials against zirconia[J]. Dent Mater, 2020, 36(3): 387-401.
[22] Flanagan D. Bite force and dental implant treatment: a short review[J]. Med Devices (Auckl), 2017, 10: 141-148.
[23] 张思佳, 曾剑玉, 李佳, 等. 三种单冠对种植体周围骨应力分布影响的光弹分析[J]. 中华口腔医学杂志, 2018, 53(1): 30-35.
Zhang SJ, Zeng JY, Li J, et al. Photoelastic analysis of the influence of prosthetic material on the stress distribution in bone around implant[J]. Chin J Stomatol, 2018, 53(1): 30-35.
[24] de Oliveira Rigotti RL, Tardelli JDC, Dos Reis AC, et al. Influence of dental implant/mini-implant design on stress distribution in overdentures: a syste-matic review[J]. Oral Maxillofac Surg, 2024, 28(2): 515-527.
[25] 李杰森, 林珍香, 吴东, 等. 不同全瓷材料和厚度的种植牙冠应力分布有限元分析[J]. 口腔疾病防治, 2021, 29(3): 166-170.
Li JS, Lin ZX, Wu D, et al. Finite element analysis of the stress distribution of dental implant crowns with different all-ceramic materials and thicknesses[J]. J Prevent Treat Stomatol Dis, 2021, 29(3): 166-170.
[26] Kaleli N, Sarac D, Külünk S, et al. Effect of diffe-rent restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: a three-dimensional finite element analysis study[J]. J Prosthet Dent, 2018, 119(3): 437-445.
[27] Martins RG, de Castro TS, Dib LL, et al. Influence of restorative material on the distribution of loads to the bone in hybrid abutment crowns: in vitro study[J]. Medicina (Kaunas), 2023, 59(7): 1188.
[28] Lin J, Cai P, Zhuo Y, et al. Effect of abutment design on fracture resistance of resin-matrix ceramic crowns for dental implant restoration: an in vitro study[J]. BMC Oral Health, 2023, 23(1): 410.
[29] Taha D, Cesar PF, Sabet A. Influence of different combinations of CAD-CAM crown and customized abutment materials on the force absorption capacity in implant supported restorations—in vitro study[J]. Dent Mater, 2022, 38(1): e10-e18.
[30] Chantler JGM, Evans CDJ, Zitzmann NU, et al. Clinical performance of single implant prostheses restored using titanium base abutments: a systema-tic review and Meta-analysis[J]. Clin Oral Implants Res, 2023, 34(): 64-85.
[31] Bjelopavlovic M, Weyhrauch M, Scheller H, et al. Retentive strength of CAD/CAM-fabricated all-ceramic crowns luted on titanium implant abutments using different ceramic materials and luting agents: an in vitro study[J]. Materials (Basel), 2022, 15(19): 6968.
[32] Cosola S, Toti P, Babetto E, et al. In-vitro fatigue and fracture performance of three different ferrulized implant connections used in fixed prosthesis[J]. J Dent Sci, 2021, 16(1): 397-403.
[33] Rohr N, Märtin S, Fischer J. Fracture load of zirconia implant supported CAD/CAM resin crowns and mechanical properties of restorative material and cement[J]. J Prosthodont Res, 2021, 65(4): 502-508.
[34] Chen CF, Trindade FZ, de Jager N, et al. The fracture resistance of a CAD/CAM Resin Nano Ceramic (RNC) and a CAD ceramic at different thicknesses[J]. Dent Mater, 2014, 30(9): 954-962.
[35] 张皓, 王秀文, 李斯文, 等. 不同表面处理方法对树脂-陶瓷复合材料微观形貌和粘接强度影响研究[J]. 中国实用口腔科杂志, 2022, 15(6): 705-710.
Zhang H, Wang XW, Li SW, et al. Study on the effect of different surface treatments on surface microstructure and bond strength of resin-ceramic hybrid material[J]. Chin J Pract Stomatol, 2022, 15(6): 705-710.
[36] Rohr N, Brunner S, Märtin S, et al. Influence of cement type and ceramic primer on retention of polymer-infiltrated ceramic crowns to a one-piece zirconia implant[J]. J Prosthet Dent, 2018, 119(1): 138-145.
[37] Çakmak G, Subaşı MG, Yilmaz B. Effect of thermocycling on the surface properties of resin-matrix CAD-CAM ceramics after different surface treatments[J]. J Mech Behav Biomed Mater, 2021, 117: 104401.
[38] Schepke U, Meijer HJ, Vermeulen KM, et al. Clinical bonding of resin nano ceramic restorations to zirconia abutments: a case series within a randomized clinical trial[J]. Clin Implant Dent Relat Res, 2016, 18(5): 984-992.
[39] Schepke U, Filius D, Lohbauer U, et al. Dimensio-nal changes of CAD/CAM polymer crowns after water aging—an in vitro experiment[J]. J Mech Behav Biomed Mater, 2022, 128: 105109.
[40] Salem MT, El-Layeh M, El-Farag SAA, et al. Clinical assessment of different implant-supported esthe-tic crown systems fabricated with semi-digital workflow: two-year prospective study[J]. J Esthet Restor Dent, 2022, 34(8): 1247-1262.
[41] Rabel K, Spies BC, Pieralli S, et al. The clinical performance of all-ceramic implant-supported single crowns: a systematic review and Meta-analysis[J]. Clin Oral Implant Res, 2018, 29(S18): 196-223.
[42] Pjetursson BE, Sailer I, Latyshev A, et al. A syste-matic review and Meta-analysis evaluating the survi-val, the failure, and the complication rates of veneered and monolithic all-ceramic implant-suppor-ted single crowns[J]. Clin Oral Implant Res, 2021, 32(S21): 254-288.
[43] Gökçimen G, Durkan R, Deste Gökay G, et al. The effect of different abutment and restorative crown materials on stress distribution in single-unit implant-supported restorations: a 3D finite element stress analysis[J]. J Prosthodont, 2024, 33(5): 497-505.
[44] Südbeck S, Hoffmann M, Reymus M, et al. Bending moment of implants restored with CAD/CAM polymer-based restoration materials with or without a titanium base before and after artificial aging[J]. Dent Mater, 2022, 38(9): e245-e255.
[45] Wendler M, Stenger A, Ripper J, et al. Mechanical degradation of contemporary CAD/CAM resin composite materials after water ageing[J]. Dent Mater, 2021, 37(7): 1156-1167.
[1] 曹周川,赵静,史珂莹,郑园娜. 打印方向对3D打印牙科氧化锆陶瓷性能影响的研究进展[J]. 国际口腔医学杂志, 2026, 53(5): 676-682.
[2] 杨光美,王剑. 全锆冠机械性能的研究现状及与临床应用的关系[J]. 国际口腔医学杂志, 2022, 49(1): 79-84.
[3] 王悦,文冰,邓梦婷,李建平. 低能量激光治疗对种植体周围组织愈合的研究进展[J]. 国际口腔医学杂志, 2021, 48(6): 725-730.
[4] 孟秀萍,侯建华,李怡然,孙梦瑶. 龈壁提升术材料选择及边缘设计的研究进展[J]. 国际口腔医学杂志, 2021, 48(3): 280-286.
[5] 季梦真,漆美瑶,杜珂芯,全淑琪,张煜强,郑庆华. 开髓洞型对全冠修复后隐裂牙抗力影响的三维有限元研究[J]. 国际口腔医学杂志, 2021, 48(1): 41-49.
[6] 王佳,李文霞,殷丽华. 缺牙区伴埋伏牙的种植修复策略[J]. 国际口腔医学杂志, 2021, 48(1): 77-81.
[7] 王素苹 程磊 周学东. 复合树脂纳米抗菌成分的研究进展[J]. 国际口腔医学杂志, 2013, 40(6): 750-753.
[8] 卿萍 高姗姗 朱卓立 樊弘毅 于海洋. 伴靠近下颌神经管埋伏牙的种植修复1 例[J]. 国际口腔医学杂志, 2012, 39(6): 736-738.
[9] 刘霜综述 张连云, 李长义审校. 口腔修复支架用钛合金的研究进展[J]. 国际口腔医学杂志, 2010, 37(3): 362-362~364.
[10] 范旭升,李志华. 镍钛合金弓丝机械性能的研究进展[J]. 国际口腔医学杂志, 2008, 35(S1): -.
[11] 康丽娟,万乾炳. 碳纳米管-羟磷灰石复合材料研究进展[J]. 国际口腔医学杂志, 2008, 35(S1): -.
[12] 米方林1,周燕玲1,黄志澎2,张杨1. 支抗力作用下上颌第一磨牙牙周膜应力的三维有限元分析[J]. 国际口腔医学杂志, 2008, 35(1): 7-9.
[13] 夏海斌. 种植体支持式单冠的固位方式及其影响因素[J]. 国际口腔医学杂志, 1999, 26(03): -.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!