摘要:

目的    研究氧化处理对镍钛合金表面亲水性的影响。方法    试验分为2 组,即经体积分数30%的过氧化氢氧化处理后的镍钛合金组和未经氧化处理过的镍钛合金组,二者皆分别滴加去离子水和α-溴萘液滴,采用接触角测量仪行静态接触角测量。结果     镍钛合金经表面氧化处理后,水与其表面的接触角和界面张力变小,合金的表面张力增加,表面润湿性、表面能以及合金与水之间的界面能等物理性能均向着有利于提高材料血液相容性的方向改善。结论  氧化处理能够有效地改善镍钛合金表面热力学性质,表面润湿性、表面能以及合金与血液之间的界面能等物理性能均向着有利于提高材料血液相容性能的方向改善。

关键词: 镍钛合金, 表面氧化, 接触角, 表面张力, 界面张力

Abstract:

Objective To evaluate the effect of oxidation on the hydrophilic property of the medical nickel titanium( NiTi) alloy. Methods The test samples were divided into two groups as a oxidized group and a non-oxidized group. NiTi alloy with nearly equiatomic ratio of nickel and titanium elements was selective oxidized in boiled 30% hydrogen peroxide solution solution. Then, the oxidized alloy was ultrasonically rinsed with deionized water and dried at 37 ℃. Static contact angle was measured using contact angle measuring instrument by stop drop method. The samples were placed in the sample room. Deionized water and α -bromonaphthalene were dropped on the samples surface. Then the measured pictures were acquired and the contact was evaluated by the accompanying software. Results The surface contact and interfacial tension of the oxidized NiTi alloy was lower than those of the non-oxidized while the surface tension was higher. The blood compatibility of the NiTi alloy will be improved by surface oxidation concerning wetting ability, interfacial tension and surface tension. Conclusion Surface thermodynamics properties including wetting ability, surface tension and interfacial tension are improved by oxidation treatment which leads to the improvement of blood compatibility of the NiTi alloy.

Key words: nickel titanium alloy, surface oxidation, contact, surface tension, interfacial tension

[1] 隋磊, 巢永烈, 王娉婷, 周敏. “亲水性”硅橡胶口腔印模材料的润湿性研究[J]. 国际口腔医学杂志, 2009, 36(4): 405-408.
[2] 范旭升,李志华. 镍钛合金弓丝机械性能的研究进展[J]. 国际口腔医学杂志, 2008, 35(S1): -.
[3] 丁少华,蔡萍,. 镍钛合金抗腐蚀性的研究进展[J]. 国际口腔医学杂志, 2007, 34(06): 467-469.
[4] 张瑜,彭彬,. 影响镍钛合金根管器械表面性状的因素[J]. 国际口腔医学杂志, 2006, 33(05): 355-357.
[5] 沈雅 彭彬 范兵. 镍钛合金机用根管器械折断的研究进展[J]. 国际口腔医学杂志, 2003, 30(03): 226-228.
[6] 宋亚玲. 非ISO机用镍钛器械成形根管的研究进展[J]. 国际口腔医学杂志, 2002, 29(01): -.
[7] 郭继华. ProFile镍钛合金根管预备器械研究进展[J]. 国际口腔医学杂志, 2000, 27(03): -.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] 张京剧. 青年期至中年期颅面复合体变化的头影测量研究[J]. 国际口腔医学杂志, 1999, 26(06): .
[2] 刘玲. 镍铬合金中铍对可铸造性和陶瓷金属结合力的影响[J]. 国际口腔医学杂志, 1999, 26(06): .
[3] 王昆润. 在种植体上制作固定义齿以后下颌骨密度的动态变化[J]. 国际口腔医学杂志, 1999, 26(06): .
[4] 王昆润. 重型颌面部炎症死亡和康复病例的实验室检查指标比较[J]. 国际口腔医学杂志, 1999, 26(06): .
[5] 逄键梁. 两例外胚层发育不良儿童骨内植入种植体后牙槽骨生长情况[J]. 国际口腔医学杂志, 1999, 26(05): .
[6] 温秀杰. 氟化物对牙本质脱矿抑制作用的体外实验研究[J]. 国际口腔医学杂志, 1999, 26(05): .
[7] 杨春惠. 耳颞神经在颞颌关节周围的分布[J]. 国际口腔医学杂志, 1999, 26(04): .
[8] 王昆润. 牙周炎加重期应选用何种抗生素[J]. 国际口腔医学杂志, 1999, 26(04): .
[9] 杨儒壮 孙宏晨 欧阳喈. 纳米级高分子支架材料在组织工程中的研究进展[J]. 国际口腔医学杂志, 2004, 31(02): 126 -128 .
[10] 严超然,李龙江. 肿瘤靶向药物载体系统的研究进展[J]. 国际口腔医学杂志, 2008, 35(S1): .