国际口腔医学杂志 ›› 2018, Vol. 45 ›› Issue (6): 686-689.doi: 10.7518/gjkq.2018.06.011
Ying Zhao,Liu Yang,Yu Xie,Yan Zhang,Wei Wei,Jiang Li()
摘要:
目的 比较不同的扫描对象对计算机辅助设计(CAD)/计算机辅助制造(CAM)钴铬烤瓷冠精确性的影响。方法 利用CAD/CAM技术制作15个钴铬烤瓷冠试件,根据不同的扫描对象:预备离体牙、硅橡胶印模和石膏模型,均分为实验B组(B1、B2和B3组),另外使用传统失蜡法铸造5个试件作为对照(A组),采用微计算机断层扫描技术比较边缘(AMD点和MG点)及内部适合性(CA点、AW点、AOT点、OA点)的差异,对结果进行单因素方差分析和配对t检验。结果 在边缘适合性上,B组AMD点的数值均明显小于A组(P<0.05),两组在MG点上的差异无统计学意义;在内部适合性上,B组除OA点外的其他位点的测量数值均小于A组,其中AOT、AW、OA点B1、2组与A组的测量差异有统计学意义(P<0.05),B3组与A组的差异无统计学意义(P>0.05);B组与A组CA点的差异均无统计学意义(P>0.05)。结论 硅橡胶印模的精确性明显优于预备后的离体牙及石膏模型,CAD/CAM相比传统失蜡铸造技术来说,试件具有更佳的边缘及内部适合性。
中图分类号:
[1] |
Mously HA, Finkelman M, Zandparsa R , et al. Mar-ginal and internal adaptation of ceramic crown resto-rations fabricated with CAD/CAM technology and the heat-press technique[J]. J Prosthet Dent, 2014,112(2):249-256.
doi: 10.1016/j.prosdent.2014.03.017 pmid: 24795263 |
[2] |
Rekow ED . Dental CAD-CAM systems. What is the state of the art[J]. J Am Dent Assoc, 1991,122(12):42-48.
doi: 10.14219/jada.archive.1991.0205 pmid: 1783723 |
[3] |
Beuer F, Schweiger J, Edelhoff D . Digital dentistry: an overview of recent developments for CAD/CAM generated restorations[J]. Br Dent J, 2008,204(9):505-511.
doi: 10.1038/sj.bdj.2008.350 pmid: 18469768 |
[4] |
Pinheiro Tannure AL, Cunha AG, Borges Junior LA , et al. Wear at the implant-abutment interface of zir-conia abutments manufactured by three CAD/CAM systems[J]. Int J Oral Maxillofac Implants, 2017,32(6):1241-1250.
doi: 10.11607/jomi.5507 pmid: 29140369 |
[5] |
Laurent M, Scheer P, Dejou J , et al. Clinical evaluation of the marginal fit of cast crowns—validation of the silicone replica method[J]. J Oral Rehabil, 2008,35(2):116-122.
doi: 10.1111/j.1365-2842.2003.01203.x |
[6] |
Borba M, Cesar PF, Griggs JA , et al. Adaptation of all-ceramic fixed partial dentures[J]. Dent Mater, 2011,27(11):1119-1126.
doi: 10.1016/j.dental.2011.08.004 pmid: 21920595 |
[7] |
Felton DA, Kanoy BE, Bayne SC , et al. Effect of in vivo crown margin discrepancies on periodontal health[J]. J Prosthet Dent, 1991,65(3):357-364.
doi: 10.1016/0022-3913(91)90225-L pmid: 2056454 |
[8] | Kocaağaoğlu H, Albayrak H, Kilinc HI , et al. Effect of repeated ceramic firings on the marginal and inte- rnal adaptation of metal-ceramic restorations fabricated with different CAD-CAM technologies[J]. J Prosthet Dent, 2017,118(5):672-677. |
[9] |
Patil A, Singh K, Sahoo S , et al. Comparative assess-ment of marginal accuracy of grade Ⅱ titanium and Ni-Cr alloy before and after ceramic firing: an in vitro study[J]. Eur J Dent, 2013,7(3):272-277.
doi: 10.4103/1305-7456.115409 |
[10] |
Fleming PS, Marinho V, Johal A . Orthodontic mea-surements on digital study models compared with plaster models: a systematic review[J]. Orthod Cra-niofac Res, 2011,14(1):1-16.
doi: 10.1111/j.1601-6343.2010.01503.x pmid: 21205164 |
[11] |
Seelbach P, Brueckel C, Wöstmann B . Accuracy of digital and conventional impression techniques and workflow[J]. Clin Oral Investig, 2013,17(7):1759-1764.
doi: 10.1007/s00784-012-0864-4 pmid: 23086333 |
[12] |
Zaruba M, Mehl A . Chairside systems: a current review[J]. Int J Comput Dent, 2017,20(2):123-149.
pmid: 28630955 |
[13] |
Miyazaki T, Hotta Y, Kunii J , et al. A review of dental CAD/CAM: current status and future perspectives from 20 years of experience[J]. Dent Mater J, 2009,28(1):44-56.
doi: 10.4012/dmj.28.44 pmid: 19280967 |
[14] |
Jörgensen KD . A new method of recording the elastic recovery of dental impression materials[J]. Scand J Dent Res, 1976,84(3):175-182.
doi: 10.1111/j.1600-0722.1976.tb00476.x pmid: 1064127 |
[1] | 杨活川综述 李彦审校. 义齿软衬和赝复体硅橡胶抗菌性的研究进展[J]. 国际口腔医学杂志, 2011, 38(5): 559-562. |
[2] | 许哲武综述 李彦审校. 颌面赝复体硅橡胶改性的研究进展[J]. 国际口腔医学杂志, 2010, 37(01): 98-98~100. |
[3] | 莫文娟综述 李彦审校. 影响颌面硅橡胶赝复体颜色的因素[J]. 国际口腔医学杂志, 2010, 37(01): 109-109~112. |
[4] | 隋磊, 巢永烈, 王娉婷, 周敏. “亲水性”硅橡胶口腔印模材料的润湿性研究[J]. 国际口腔医学杂志, 2009, 36(4): 405-408. |
[5] | 柳文娟 李四群 李志安 黄翠. 硅橡胶印模材料表面润湿性的研究进展[J]. 国际口腔医学杂志, 2003, 30(06): 464-466. |
|