国际口腔医学杂志 ›› 2017, Vol. 44 ›› Issue (3): 344-349.doi: 10.7518/gjkq.2017.03.019

• 综述 • 上一篇    下一篇

计算机辅助设计与制作钛支架在无牙颌患者种植固定修复中的应用现状

李燕玲, 王劲茗   

  1. 中山大学光华口腔医学院•
    附属口腔医院种植科;广东省口腔医学重点实验室 广州 510055
  • 收稿日期:2016-07-16 修回日期:2016-11-20 出版日期:2017-05-01 发布日期:2017-05-01
  • 通讯作者: 王劲茗,副教授,博士,Email:wjinm@mail.sysu.edu.cn
  • 作者简介:李燕玲,硕士,Email:liyanl7@mail2.sysu.edu.cn

Application of computer-aided design and computer-aided manufacturing of milled titanium framework in the implant-support rehabilitation of edentulous patients

Li Yanling, Wang Jinming.   

  1. Guanghua School of Stomatology, Dept. of Implantology, Hospital of Stomatology, Sun Yat-sen University;
    Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China
  • Received:2016-07-16 Revised:2016-11-20 Online:2017-05-01 Published:2017-05-01

摘要: 计算机辅助设计与制作(CAD/CAM)系统应用于种植修复已有多年历史,其快速发展和不断完善为口腔种植修复治疗提供越来越广泛的服务。CAD/CAM 切削全牙列钛支架相比铸造支架,精密度高,密合性好,就位良好,节省椅旁时间并简化操作步骤。本文就CAD/CAM 钛支架制作过程以及近期内在无牙颌患者种植固定修复的应用作一综述。

关键词: 计算机辅助设计与制作, 钛支架, 无牙颌, 种植固定修复

Abstract: Computer-aided design and computer-aided manufacturing(CAD/CAM) has been widely used in implantology for a long time. The rapid development and improvement of such method have broadened the scope of prosthetic implant treatments and brought profound changes to the implantology industry. Compared with casting alloy framework, CAD/CAM milled titanium framework has the advantages of precision, aesthetics and passive fit, time efficiency, and simplicity of procedure. The application of CAD/CAM milled titanium framework in the implant-supported fixed rehabilitation of edentulous patients was reviewed.

Key words: computer-aided design and computer-aided manufacturing, milled titanium framework, edentulous, implant-support fixed rehabilitation

中图分类号: 

  • R783.4
[1] Drago C, Howell K. Concepts for designing and fabricating metal implant frameworks for hybrid implant prostheses[J]. J Prosthodont, 2012, 21(5): 413-424.
[2] Patzelt SB, Emmanouilidi A, Stampf S, et al. Ac-curacy of full-arch scans using intraoral scanners[J]. Clin Oral Investig, 2014,18(6):1687-1694.
[3] Pozzi A, Tallarico M, Mangani F, et al. Different im-plant impression techniques for edentulous patients treated with CAD/CAM complete-arch prostheses: a randomised controlled trial reporting data at 3 years post-loading[J]. Eur J Oral Implantol, 2013, 6(4): 325-340.
[4] Shqaidef A, Ayoub AF, Khambay BS. How accurate are rapid prototyped(RP) final orthognathic surgical wafers? A pilot study[J]. Br J Oral Maxillofac Surg, 2014, 52(7):609-614.
[5] Miyazaki T, Hotta Y. CAD/CAM systems available for the fabrication of crown and bridge restorations [J]. Aust Dent J, 2011, 56(Suppl 1):97-106.
[6] Kapos T, Evans C. CAD/CAM technology for im-plant abutments, crowns, and superstructures[J]. Int J Oral Maxillofac Implants, 2014, 29(Suppl):117- 136.
[7] El-Hajje A, Kolos EC, Wang JK, et al. Physical and mechanical characterisation of 3D-printed porous titanium for biomedical applications[J]. J Mater Sci Mater Med, 2014, 25(11):2471-2480.
[8] Lin WS, Harris BT, Zandinejad A, et al. Use of di-gital data acquisition and CAD/CAM technology for the fabrication of a fixed complete dental prosthesis on dental implants[J]. J Prosthet Dent, 2014, 111(1): 1-5.
[9] Dennison JB, Sarrett DC. Prediction and diagnosis of clinical outcomes affecting restoration margins[J]. J Oral Rehabil, 2012, 39(4):301-318.
[10] Serino G, Strom C. Peri-implantitis in partially eden-tulous patients: association with inadequate plaque control[J]. Clin Oral Implants Res, 2009, 20(2):169- 174.
[11] Eliasson A, Wennerberg A, Johansson A, et al. The precision of fit of milled titanium implant frame works(I-Bridge) in the edentulous jaw[J]. Clin Implant Dent Relat Res, 2010, 12(2):81-90.
[12] Al-Fadda SA, Zarb GA, Finer Y. A comparison of the accuracy of fit of 2 methods for fabricating im-plant-prosthodontic frameworks[J]. Int J Prosthodont, 2007, 20(2):125-131.
[13] Alfadda SA. Vertical marginal gap evaluation of conventional cast and computer numeric controlled-milled titanium full-arch implant-supported frame-works[J]. Int J Prosthodont, 2014, 27(6):517-522.
[14] Sierraalta M, Vivas JL, Razzoog ME, et al. Precision of fit of titanium and cast implant frameworks using a new matching formula[J]. Int J Dent, 2012, 2012: 374315.
[15] Örtorp A, Jemt T, Jalevik T. Comparisons of pre-cision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible[J]. Int J Prosthodont, 2003, 16(2):194-200.
[16] Almasri R, Drago CJ, Siegel SC, et al. Volumetric misfit in CAD/CAM and cast implant frameworks: a university laboratory study[J]. J Prosthodont, 2011, 20(4):267-274.
[17] Katsoulis J, Müller P, Mericske-Stern R. CAD/CAM fabrication accuracy of long- vs. short-span implant-supported FDPs[J]. Clin Oral Implants Res, 2015, 26(3):245-249.
[18] Meloni SM, De Riu G, Pisano M, et al. Implant re-storation of edentulous jaws with 3D software plann-ing, guided surgery, immediate loading, and CAD-CAM full arch frameworks[J]. Int J Dent, 2013, 2013:683423.
[19] Örtorp A, Jemt T. CNC-milled titanium frameworks supported by implants in the edentulous jaw: a 10- year comparative clinical study[J]. Clin Implant Dent Relat Res, 2012, 14(1):88-99.
[20] Örtorp A, Jemt T. Clinical experiences of computer numeric control-milled titanium frameworks sup-ported by implants in the edentulous jaw: a 5-year prospective study[J]. Clin Implant Dent Relat Res, 2004, 6(4):199-209.
[21] Gomes ÉA, Tiossi R, Faria AC, et al. Torque loss under mechanical cycling of long-span zirconia and titanium-cemented and screw-retained implant-sup-ported CAD/CAM frameworks[J]. Clin Oral Im-plants Res, 2014, 25(12):1395-1402.
[22] Ehrenkranz H, Langer B, Marotta L. Complete-arch maxillary rehabilitation using a custom-designed and manufactured titanium framework: a clinical report [J]. J Prosthet Dent, 2008, 99(1):8-13.
[23] Bacchi A, Paludo L, Ferraz Mesquita M, et al. Loosening torque of prosthetic screws in metal-ceramic or metal-acrylic resin implant-supported dentures with different misfit levels[J]. J Biomech, 2013, 46(7):1358-1362.
[24] Farina AP, Spazzin AO, Consani RL, et al. An in vitro comparison of joint stability of implant-sup-ported fixed prosthetic suprastructures retained with different prosthetic screws and levels of fit under masticatory simulation conditions[J]. Int J Oral Max-illofac Implants, 2012, 27(4):833-838.
[25] Örtorp A, Jemt T. Clinical experiences of computer numeric control-milled titanium frameworks suppor-ted by implants in the edentulous jaw: a 3-year interim report[J]. Clin Implant Dent Relat Res, 2002, 4(2): 104-109.
[26] Drago C. Ratios of cantilever lengths and anterior-posterior spreads of definitive hybrid full-arch, screw-retained prostheses: results of a clinical study [J]. J Prosthodont, 2016, doi:10.1111/jopr. 12519.
[27] Dittmer MP, Nensa M, Stiesch M, et al. Load-bearing capacity of screw-retained CAD/CAM-produced titanium implant frameworks(I-Bridge ® 2) before and after cyclic mechanical loading[J]. J Appl Oral Sci, 2013, 21(4):307-313.
[28] Takahashi T, Gunne J. Fit of implant frameworks: an in vitro comparison between two fabrication techni-ques[J]. J Prosthet Dent, 2003, 89(3):256-260.
[29] Roberto De Santis, Antonio Gloria, Teresa Russo. Reverse engineering of mandible and prosthetic framework: effect of titanium implants in conjunc-tion with titanium milled full arch bridge prostheses on the biomechanics of the mandible[J]. J Biomech, 2014, 47(16):3825-3829.
[30] Ferreira MB, Barao VA, Faverani LP, et al. The role of superstructure material on the stress distribution in mandibular full-arch implant-supported fixed dentures. A CT-based 3D-FEA[J]. Mater Sci Eng C Mater Biol Appl, 2014, 35:92-99.
[31] Taira Y, Odatsu T, Sawase T. Effects of a fluoride etchant and a phosphate primer on bonding of vene-ering composite to Ti-6Al-4V alloy for CAD/CAM restorations[J]. J Prosthod Res, 2013, 57(1):30-35.
[32] Lin MC, Huang HH. Improvement in dental por-celain bonding to milled, noncast titanium surfaces by gold sputter coating[J]. J Prosthodont, 2014, 23 (7):540-548.
[33] Harder S, Kern M. Survival and complications of computer aided-designing and computer-aided manufacturing vs. conventionally fabricated implant-supported reconstructions: a systematic review[J]. Clin Oral Implants Res, 2009, 20(Suppl 4):48-54.
[1] 汤春波. 无牙颌患者种植治疗修复空间与修复方式的选择策略[J]. 国际口腔医学杂志, 2024, 51(1): 1-9.
[2] 雒琪玥,柳叶语,罗依麟,满毅. 以正中关系为中心、面部美学及修复为导向的数字化无牙颌种植修复1例[J]. 国际口腔医学杂志, 2022, 49(4): 426-431.
[3] 章婷婷,胡常红,彭燕,周文翘,张慧聪,刘蝶. 300例不同年龄段有牙颌人群上唇软组织侧貌的锥形束CT三维测量分析[J]. 国际口腔医学杂志, 2020, 47(2): 182-188.
[4] 付栩楠,谢志刚. 种植固定修复中基台机械并发症的研究进展[J]. 国际口腔医学杂志, 2019, 46(5): 571-577.
[5] 胡常红. 回归治疗本质的无牙颌修复理念[J]. 国际口腔医学杂志, 2018, 45(6): 621-627.
[6] 肖静1 滕伟2. 三维数字化扫描在口腔修复领域中的应用[J]. 国际口腔医学杂志, 2014, 41(1): 63-67.
[7] 孙惠强1,2 刘金2. 全口义齿印模技术的进展介绍[J]. 国际口腔医学杂志, 2013, 40(6): 701-705.
[8] 江鹭鹭 封伟 张娇 邓春富 张翀 尚德浩 王华 赵宝红. 不同类型附着体种植覆盖义齿的临床疗效评价[J]. 国际口腔医学杂志, 2013, 40(3): 312-314.
[9] 宋应亮. 无牙颌种植修复固位的并发症与处理[J]. 国际口腔医学杂志, 2013, 40(1): 3-5.
[10] 邵琦1 孙惠强1,2 邓艳南1 万浩元1. 中性区技术在义齿制作中的应用[J]. 国际口腔医学杂志, 2012, 39(2): 174-176.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] 张新春. 桩冠修复与无髓牙的保护[J]. 国际口腔医学杂志, 1999, 26(06): .
[2] 王昆润. 长期单侧鼻呼吸对头颅发育有不利影响[J]. 国际口腔医学杂志, 1999, 26(05): .
[3] 彭国光. 颈淋巴清扫术中颈交感神经干的解剖变异[J]. 国际口腔医学杂志, 1999, 26(05): .
[4] 杨凯. 淋巴化疗的药物运载系统及其应用现状[J]. 国际口腔医学杂志, 1999, 26(05): .
[5] 康非吾. 种植义齿下部结构生物力学研究进展[J]. 国际口腔医学杂志, 1999, 26(05): .
[6] 柴枫. 可摘局部义齿用Co-Cr合金的激光焊接[J]. 国际口腔医学杂志, 1999, 26(04): .
[7] 孟姝,吴亚菲,杨禾. 伴放线放线杆菌产生的细胞致死膨胀毒素及其与牙周病的关系[J]. 国际口腔医学杂志, 2005, 32(06): 458 -460 .
[8] 费晓露,丁一,徐屹. 牙周可疑致病菌对口腔黏膜上皮的粘附和侵入[J]. 国际口腔医学杂志, 2005, 32(06): 452 -454 .
[9] 赵兴福,黄晓晶. 变形链球菌蛋白组学研究进展[J]. 国际口腔医学杂志, 2008, 35(S1): .
[10] 庞莉苹,姚江武. 抛光和上釉对陶瓷表面粗糙度、挠曲强度及磨损性能的影响[J]. 国际口腔医学杂志, 2008, 35(S1): .