国际口腔医学杂志 ›› 2016, Vol. 43 ›› Issue (5): 515-518.doi: 10.7518/gjkq.2016.05.006

• 论著 • 上一篇    下一篇

Digora及Propex测量根管工作长度准确性的比较研究

梁继超 王芬 张凤英 张正华 侯梅娟 庞富生 周锋   

  1. 云南省曲靖市第一人民医院口腔科 曲靖 655000
  • 收稿日期:2016-01-15 修回日期:2016-04-06 出版日期:2016-09-01 发布日期:2016-09-01
  • 通讯作者: 王芬,主任医师,硕士,Email:530381@163.com
  • 作者简介:梁继超,主治医师,硕士,Email:125489802@qq.com

Comparison of the accuracy of Digora and Propex on the measurement of working length of root canal

Liang Jichao, Wang Fen, Zhang Fengying, Zhang Zhenghua, Hou Meijuan, Pang Fusheng, Zhou Feng   

  1. Dept. of Stomatology, The First People’s Hospital of Qujing in Yunnan Province, Qujing 655000, China
  • Received:2016-01-15 Revised:2016-04-06 Online:2016-09-01 Published:2016-09-01

摘要: 目的 评价数字化牙片系统Digora及电子根尖定位仪Propex测量根管工作长度的准确性,为临床应用提供参考依据。方法 选取临床中需拔牙的90例患者260颗患牙(369个牙根)为研究对象,首先对患牙拍摄数字化牙片,利用Digora系统中的长度工具测量牙片上牙齿根管长度,然后对患牙开髓,电子根尖定位仪Propex测量根管工作长度,最后拔除患牙直视下测量根管实际长度并以此长度为标准,计算Digora牙片测量法、Propex电测法与实际根管长度的差值,分别以1、1.5 mm误差评定两法测量根管工作长度的准确性。结果 牙片法测量值与拔牙实测值差值为(2.163±1.194)mm,电测法测量值与拔牙实测值差值为(0.214±0.542)mm。以1 mm内为可接受范围,牙片法准确率为21.68%,电测法为91.87%;若以1.5 mm以内为可接受范围,则两法准确率分别为30.35%、95.66%。牙片法准确率均明显低于电测法(P<0.01)。结论 采用Digora系统长度工具直接测量牙片上根管长度时,误差较大,不能直接指导临床操作。Propex能较准确地测量根管工作长度。

关键词: 根管治疗术, 根管工作长度, Digora, Propex

Abstract: Objective This study aimed to compare the accuracy of the X-ray digital imaging system Digora and the electronic apex locator Propex on the measurement of the working length of root canal. Methods The study comprised 260 teeth(369 roots)that needed to be extracted from 90 patients. Each tooth was radiographed with the Digora system, and the root length was measured in the Digora digital imaging software with the length tool. The teeth were anesthetized and accessed. The working length of the root canal was determined by the apex locator Propex. Finally, the tooth was extracted, and the real length of the root canal was measured directly. The results obtained with Digora and Propex were compared with the real length. Results The difference between the Digora measured length and real length was (2.163±1.194) mm, where as that between the Propex measured length and real length was (0.214±0.542) mm. When a difference of less than 1 mm was acceptable, the measurement accuracy of Digora and Propex was 21.68% and 91.87%, respectively. When a difference of less than 1.5 mm was acceptable, the accuracy of Digora and Propex was 30.35% and 95.66%, respectively. The measurement accuracy of Digora was significantly lower than that of Propex(P<0.01). Conclusion Digora could easily directly evaluate the root canal length, but it could not directly guide clinical operations. Propex could accurately measure the working length of the root canal.

Key words: root canal therapy, root canal working length, Digora; Propex

中图分类号: 

  • R 781.05
[1] 谭咏梅 招少萍 闫文娟 张海兰 吕文杰 周丽娟. 一次根管治疗术与两次根管治疗术术后短期临床疗效的比较[J]. 国际口腔医学杂志, 2014, 41(3): 277-280.
[2] 黄林, 牛卫东. 不同根管环境对Root ZX 和ProPex 准确性的影响研究[J]. 国际口腔医学杂志, 2010, 37(01): 23-25,29.
[3] 葛兵, 倪海林, 黄娟, 吴友农. 2 种方法根管充填后牙根疲劳强度的体外研究[J]. 国际口腔医学杂志, 2009, 36(5): 527-530.
[4] 刘思逸,梅陵宣,. 根管长度电测法的发展史及现状[J]. 国际口腔医学杂志, 2006, 33(05): 361-363.
[5] 梁睿贞,吴友农,. 上颌磨牙近颊根第二根管的预备及充填[J]. 国际口腔医学杂志, 2006, 33(05): 367-368.
[6] 陈书兰. 根管超声冲洗研究进展[J]. 国际口腔医学杂志, 2002, 29(06): -.
[7] 雷芳. 直接数字式摄影系统在牙体牙髓病临床的应用[J]. 国际口腔医学杂志, 2000, 27(03): -.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] 王昆润. 修补颌骨缺损的新型生物学相容材料[J]. 国际口腔医学杂志, 1999, 26(06): .
[2] 陆加梅. 不可复性关节盘移位患者术前张口度与关节镜术后疗效的相关性[J]. 国际口腔医学杂志, 1999, 26(06): .
[3] 宋红. 青少年牙周炎外周血分叶核粒细胞的趋化功能[J]. 国际口腔医学杂志, 1999, 26(06): .
[4] 高卫民,李幸红. 发达国家牙医学院口腔种植学教学现状[J]. 国际口腔医学杂志, 1999, 26(06): .
[5] 侯锐. 正畸患者釉白斑损害的纵向激光荧光研究[J]. 国际口腔医学杂志, 1999, 26(05): .
[6] 轩东英. 不同赋形剂对氢氧化钙抗菌效果的影响[J]. 国际口腔医学杂志, 1999, 26(05): .
[7] 房兵. 唇腭裂新生儿前颌骨矫正方法及对上颌骨生长发育的影响[J]. 国际口腔医学杂志, 1999, 26(05): .
[8] 杨美祥. 前牙厚度在预测上下颌牙量协调性中的作用[J]. 国际口腔医学杂志, 1999, 26(04): .
[9] 赵艳丽. 手术刀、电凝、CO_2和KTP激光对大鼠舌部创口的作用[J]. 国际口腔医学杂志, 1999, 26(04): .
[10] 康健,华成舸. 术前诱导化疗在头颈部肿瘤预后评价中的意义[J]. 国际口腔医学杂志, 2008, 35(S1): .